Export limit exceeded: 361547 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (361547 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-68774 | 1 Linux | 1 Linux Kernel | 2026-04-15 | 5.5 Medium |
| In the Linux kernel, the following vulnerability has been resolved: hfsplus: fix missing hfs_bnode_get() in __hfs_bnode_create When sync() and link() are called concurrently, both threads may enter hfs_bnode_find() without finding the node in the hash table and proceed to create it. Thread A: hfsplus_write_inode() -> hfsplus_write_system_inode() -> hfs_btree_write() -> hfs_bnode_find(tree, 0) -> __hfs_bnode_create(tree, 0) Thread B: hfsplus_create_cat() -> hfs_brec_insert() -> hfs_bnode_split() -> hfs_bmap_alloc() -> hfs_bnode_find(tree, 0) -> __hfs_bnode_create(tree, 0) In this case, thread A creates the bnode, sets refcnt=1, and hashes it. Thread B also tries to create the same bnode, notices it has already been inserted, drops its own instance, and uses the hashed one without getting the node. ``` node2 = hfs_bnode_findhash(tree, cnid); if (!node2) { <- Thread A hash = hfs_bnode_hash(cnid); node->next_hash = tree->node_hash[hash]; tree->node_hash[hash] = node; tree->node_hash_cnt++; } else { <- Thread B spin_unlock(&tree->hash_lock); kfree(node); wait_event(node2->lock_wq, !test_bit(HFS_BNODE_NEW, &node2->flags)); return node2; } ``` However, hfs_bnode_find() requires each call to take a reference. Here both threads end up setting refcnt=1. When they later put the node, this triggers: BUG_ON(!atomic_read(&node->refcnt)) In this scenario, Thread B in fact finds the node in the hash table rather than creating a new one, and thus must take a reference. Fix this by calling hfs_bnode_get() when reusing a bnode newly created by another thread to ensure the refcount is updated correctly. A similar bug was fixed in HFS long ago in commit a9dc087fd3c4 ("fix missing hfs_bnode_get() in __hfs_bnode_create") but the same issue remained in HFS+ until now. | ||||
| CVE-2023-36512 | 2 Woo, Wordpress | 2 Automatewoo, Wordpress | 2026-04-15 | 6.5 Medium |
| Missing Authorization vulnerability in Woo AutomateWoo.This issue affects AutomateWoo: from n/a through 5.7.5. | ||||
| CVE-2025-68783 | 1 Linux | 1 Linux Kernel | 2026-04-15 | 5.5 Medium |
| In the Linux kernel, the following vulnerability has been resolved: ALSA: usb-mixer: us16x08: validate meter packet indices get_meter_levels_from_urb() parses the 64-byte meter packets sent by the device and fills the per-channel arrays meter_level[], comp_level[] and master_level[] in struct snd_us16x08_meter_store. Currently the function derives the channel index directly from the meter packet (MUB2(meter_urb, s) - 1) and uses it to index those arrays without validating the range. If the packet contains a negative or out-of-range channel number, the driver may write past the end of these arrays. Introduce a local channel variable and validate it before updating the arrays. We reject negative indices, limit meter_level[] and comp_level[] to SND_US16X08_MAX_CHANNELS, and guard master_level[] updates with ARRAY_SIZE(master_level). | ||||
| CVE-2025-62065 | 1 Wordpress | 1 Wordpress | 2026-04-15 | 9.9 Critical |
| Unrestricted Upload of File with Dangerous Type vulnerability in Rometheme RTMKit rometheme-for-elementor.This issue affects RTMKit: from n/a through <= 1.6.5. | ||||
| CVE-2024-43647 | 1 Siemens | 14 Simatic S7-200 Smart Cpu Cr20s, Simatic S7-200 Smart Cpu Cr30s, Simatic S7-200 Smart Cpu Cr40 and 11 more | 2026-04-15 | 7.5 High |
| A vulnerability has been identified in SIMATIC S7-200 SMART CPU CR40 (6ES7288-1CR40-0AA0) (All versions), SIMATIC S7-200 SMART CPU CR60 (6ES7288-1CR60-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR30 (6ES7288-1SR30-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR30 (6ES7288-1SR30-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR40 (6ES7288-1SR40-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR40 (6ES7288-1SR40-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR60 (6ES7288-1SR60-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR60 (6ES7288-1SR60-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST20 (6ES7288-1ST20-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST20 (6ES7288-1ST20-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST30 (6ES7288-1ST30-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST30 (6ES7288-1ST30-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST40 (6ES7288-1ST40-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST40 (6ES7288-1ST40-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST60 (6ES7288-1ST60-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST60 (6ES7288-1ST60-0AA1) (All versions). Affected devices do not properly handle TCP packets with an incorrect structure. This could allow an unauthenticated remote attacker to cause a denial of service condition. To restore normal operations, the network cable of the device needs to be unplugged and re-plugged. | ||||
| CVE-2024-43781 | 2026-04-15 | 5.5 Medium | ||
| A vulnerability has been identified in SINUMERIK 828D V4 (All versions < V4.95 SP3), SINUMERIK 840D sl V4 (All versions < V4.95 SP3 in connection with using Create MyConfig (CMC) <= V4.8 SP1 HF6), SINUMERIK ONE (All versions < V6.23 in connection with using Create MyConfig (CMC) <= V6.6), SINUMERIK ONE (All versions < V6.15 SP4 in connection with using Create MyConfig (CMC) <= V6.6). Affected systems, that have been provisioned with Create MyConfig (CMC), contain a Insertion of Sensitive Information into Log File vulnerability. This could allow a local authenticated user with low privileges to read sensitive information and thus circumvent access restrictions. | ||||
| CVE-2025-68786 | 1 Linux | 1 Linux Kernel | 2026-04-15 | N/A |
| In the Linux kernel, the following vulnerability has been resolved: ksmbd: skip lock-range check on equal size to avoid size==0 underflow When size equals the current i_size (including 0), the code used to call check_lock_range(filp, i_size, size - 1, WRITE), which computes `size - 1` and can underflow for size==0. Skip the equal case. | ||||
| CVE-2025-68193 | 1 Linux | 1 Linux Kernel | 2026-04-15 | 5.5 Medium |
| In the Linux kernel, the following vulnerability has been resolved: drm/xe/guc: Add devm release action to safely tear down CT When a buffer object (BO) is allocated with the XE_BO_FLAG_GGTT_INVALIDATE flag, the driver initiates TLB invalidation requests via the CTB mechanism while releasing the BO. However a premature release of the CTB BO can lead to system crashes, as observed in: Oops: Oops: 0000 [#1] SMP NOPTI RIP: 0010:h2g_write+0x2f3/0x7c0 [xe] Call Trace: guc_ct_send_locked+0x8b/0x670 [xe] xe_guc_ct_send_locked+0x19/0x60 [xe] send_tlb_invalidation+0xb4/0x460 [xe] xe_gt_tlb_invalidation_ggtt+0x15e/0x2e0 [xe] ggtt_invalidate_gt_tlb.part.0+0x16/0x90 [xe] ggtt_node_remove+0x110/0x140 [xe] xe_ggtt_node_remove+0x40/0xa0 [xe] xe_ggtt_remove_bo+0x87/0x250 [xe] Introduce a devm-managed release action during xe_guc_ct_init() and xe_guc_ct_init_post_hwconfig() to ensure proper CTB disablement before resource deallocation, preventing the use-after-free scenario. | ||||
| CVE-2024-44087 | 1 Siemens | 1 Automation License Manager | 2026-04-15 | 8.6 High |
| A vulnerability has been identified in Automation License Manager V5 (All versions), Automation License Manager V6.0 (All versions < V6.0 SP12 Upd3), Automation License Manager V6.2 (All versions < V6.2 Upd3). Affected applications do not properly validate certain fields in incoming network packets on port 4410/tcp. This could allow an unauthenticated remote attacker to cause an integer overflow and crash of the application. This denial of service condition could prevent legitimate users from using subsequent products that rely on the affected application for license verification. | ||||
| CVE-2025-68195 | 1 Linux | 1 Linux Kernel | 2026-04-15 | N/A |
| In the Linux kernel, the following vulnerability has been resolved: x86/CPU/AMD: Add missing terminator for zen5_rdseed_microcode Running x86_match_min_microcode_rev() on a Zen5 CPU trips up KASAN for an out of bounds access. | ||||
| CVE-2025-6242 | 1 Redhat | 2 Ai Inference Server, Enterprise Linux Ai | 2026-04-15 | 7.1 High |
| A Server-Side Request Forgery (SSRF) vulnerability exists in the MediaConnector class within the vLLM project's multimodal feature set. The load_from_url and load_from_url_async methods fetch and process media from user-provided URLs without adequate restrictions on the target hosts. This allows an attacker to coerce the vLLM server into making arbitrary requests to internal network resources. | ||||
| CVE-2024-44116 | 2026-04-15 | 4.3 Medium | ||
| The RFC enabled function module allows a low privileged user to add any workbook to any user's workplace favourites. This vulnerability could be utilized to identify usernames and access information about targeted user's workplaces. There is low impact on integrity of the application. | ||||
| CVE-2024-44120 | 1 Sap | 1 Netweaver Enterprise Portal | 2026-04-15 | 4.7 Medium |
| SAP NetWeaver Enterprise Portal is vulnerable to reflected cross site scripting due to insufficient encoding of user-controlled input. An unauthenticated attacker could craft a malicious URL and trick a user to click it. If the victim clicks on this crafted URL before it times out, then the attacker could read and manipulate user content in the browser. | ||||
| CVE-2024-44121 | 2026-04-15 | 4.3 Medium | ||
| Under certain conditions Statutory Reports in SAP S/4 HANA allows an attacker with basic privileges to access information which would otherwise be restricted. The vulnerability could expose internal user data that should remain confidential. It does not impact the integrity and availability of the application | ||||
| CVE-2025-68209 | 1 Linux | 1 Linux Kernel | 2026-04-15 | 7.0 High |
| In the Linux kernel, the following vulnerability has been resolved: mlx5: Fix default values in create CQ Currently, CQs without a completion function are assigned the mlx5_add_cq_to_tasklet function by default. This is problematic since only user CQs created through the mlx5_ib driver are intended to use this function. Additionally, all CQs that will use doorbells instead of polling for completions must call mlx5_cq_arm. However, the default CQ creation flow leaves a valid value in the CQ's arm_db field, allowing FW to send interrupts to polling-only CQs in certain corner cases. These two factors would allow a polling-only kernel CQ to be triggered by an EQ interrupt and call a completion function intended only for user CQs, causing a null pointer exception. Some areas in the driver have prevented this issue with one-off fixes but did not address the root cause. This patch fixes the described issue by adding defaults to the create CQ flow. It adds a default dummy completion function to protect against null pointer exceptions, and it sets an invalid command sequence number by default in kernel CQs to prevent the FW from sending an interrupt to the CQ until it is armed. User CQs are responsible for their own initialization values. Callers of mlx5_core_create_cq are responsible for changing the completion function and arming the CQ per their needs. | ||||
| CVE-2025-68787 | 1 Linux | 1 Linux Kernel | 2026-04-15 | N/A |
| In the Linux kernel, the following vulnerability has been resolved: netrom: Fix memory leak in nr_sendmsg() syzbot reported a memory leak [1]. When function sock_alloc_send_skb() return NULL in nr_output(), the original skb is not freed, which was allocated in nr_sendmsg(). Fix this by freeing it before return. [1] BUG: memory leak unreferenced object 0xffff888129f35500 (size 240): comm "syz.0.17", pid 6119, jiffies 4294944652 hex dump (first 32 bytes): 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ................ 00 00 00 00 00 00 00 00 00 10 52 28 81 88 ff ff ..........R(.... backtrace (crc 1456a3e4): kmemleak_alloc_recursive include/linux/kmemleak.h:44 [inline] slab_post_alloc_hook mm/slub.c:4983 [inline] slab_alloc_node mm/slub.c:5288 [inline] kmem_cache_alloc_node_noprof+0x36f/0x5e0 mm/slub.c:5340 __alloc_skb+0x203/0x240 net/core/skbuff.c:660 alloc_skb include/linux/skbuff.h:1383 [inline] alloc_skb_with_frags+0x69/0x3f0 net/core/skbuff.c:6671 sock_alloc_send_pskb+0x379/0x3e0 net/core/sock.c:2965 sock_alloc_send_skb include/net/sock.h:1859 [inline] nr_sendmsg+0x287/0x450 net/netrom/af_netrom.c:1105 sock_sendmsg_nosec net/socket.c:727 [inline] __sock_sendmsg net/socket.c:742 [inline] sock_write_iter+0x293/0x2a0 net/socket.c:1195 new_sync_write fs/read_write.c:593 [inline] vfs_write+0x45d/0x710 fs/read_write.c:686 ksys_write+0x143/0x170 fs/read_write.c:738 do_syscall_x64 arch/x86/entry/syscall_64.c:63 [inline] do_syscall_64+0xa4/0xfa0 arch/x86/entry/syscall_64.c:94 entry_SYSCALL_64_after_hwframe+0x77/0x7f | ||||
| CVE-2024-44667 | 1 Shenzhen Haichangxing Technology | 1 Hcx H822 Firmware | 2026-04-15 | 8 High |
| Shenzhen Haichangxing Technology Co., Ltd HCX H822 4G LTE Router M7628NNxISPxUIv2_v1.0.1557.15.35_P0 is vulnerable to Incorrect Access Control. Unauthenticated factory mode reset and command injection leads to information exposure and root shell access. | ||||
| CVE-2024-44786 | 1 Meabillis Cms | 1 Meabillis Cms | 2026-04-15 | 7.5 High |
| Incorrect access control in Meabilis CMS 1.0 allows attackers to access other users' address books via unspecified vectors. | ||||
| CVE-2025-12387 | 1 Pix-link | 1 Lv-wr21q | 2026-04-15 | N/A |
| A vulnerability in the Pix-Link LV-WR21Q router's language module allows remote attackers to trigger a denial of service (DoS) by sending a specially crafted HTTP POST request containing non-existing language parameter. This renders the server unable to serve correct lang.js file, which causes administrator panel to not work, resulting in DoS until the language settings is reverted to a correct value. The Denial of Service affects only the administrator panel and does not affect other router functionalities. The vendor was notified early about this vulnerability, but didn't respond with the details of vulnerability or vulnerable version range. Only version V108_108 was tested and confirmed as vulnerable, other versions were not tested and might also be vulnerable. | ||||
| CVE-2024-45032 | 1 Siemens | 2 Industrial Edge Management Pro, Industrial Edge Management Virtual | 2026-04-15 | 10 Critical |
| A vulnerability has been identified in Industrial Edge Management Pro (All versions < V1.9.5), Industrial Edge Management Virtual (All versions < V2.3.1-1). Affected components do not properly validate the device tokens. This could allow an unauthenticated remote attacker to impersonate other devices onboarded to the system. | ||||