Search
Search Results (5 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2026-16938 | 1 Ibm | 19 Power System E1080 \(9080-hex\), Power System E1080 \(9080-hex\) Firmware, Power System E1180 \(9080-heu\) and 16 more | 2026-08-25 | 6.9 Medium |
| IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in access controls over privileged system configuration operations on the FSP. An attacker with authenticated administrator-level access to the FSP can place the managed system into a non-production operational mode, allowing certain system components to be disabled. This condition persists across FSP resets and requires explicit operator intervention — clearing the affected configuration — to restore normal operation. Successful exploitation results in an availability impact to the managed system. | ||||
| CVE-2026-16687 | 1 Ibm | 19 Power System E1080 \(9080-hex\), Power System E1080 \(9080-hex\) Firmware, Power System E1180 \(9080-heu\) and 16 more | 2026-08-25 | 9.6 Critical |
| IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the ASMI web interface. An unauthenticated attacker with network access can send the FSP a malformed request, allowing arbitrary code execution, giving the attacker full control over the managed system, resulting in a confidentiality, integrity, and availability impact. | ||||
| CVE-2026-16933 | 1 Ibm | 59 Power Hardware Management Console \(7063-cr2\), Power Hardware Management Console \(7063-cr2\) Firmware, Power System Ac922 \(8335-gth\) and 56 more | 2026-08-25 | 8.2 High |
| IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, FW950.00 through FW950.H2, OP940.00 through OP940.a1 (Power9), and OP940.00 through OP940.81 (Power HMC) is affected by a vulnerability in the interface between the BMC/FSP and the host system. An attacker with service account or root access to the BMC/FSP can read and write arbitrary regions of host system memory, giving full control over the host system and all hosted partitions, resulting in a confidentiality, integrity, and availability impact. | ||||
| CVE-2026-17063 | 1 Ibm | 39 Power System E1050 \(9043-mrx\), Power System E1050 \(9043-mrx\) Firmware, Power System E1080 \(9080-hex\) and 36 more | 2026-08-25 | 7.9 High |
| IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, and FW1060.00 through FW1060.80 is affected by a vulnerability in the interface between the BMC/FSP and the host system. An attacker with service account or root access to the BMC/FSP can access and disrupt host processor state, potentially affecting the managed system and all hosted partitions, resulting in an confidentiality, and availability impact. | ||||
| CVE-2026-16930 | 1 Ibm | 39 Power System E1050 \(9043-mrx\), Power System E1050 \(9043-mrx\) Firmware, Power System E1080 \(9080-hex\) and 36 more | 2026-08-24 | 8.2 High |
| IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, and FW1060.00 through FW1060.80 is affected by a vulnerability in the interface between the BMC/FSP and the host system. An attacker with service account or root access to the BMC/FSP can execute arbitrary code on the host system, giving full control over the host system and all hosted partitions, resulting in a confidentiality, integrity, and availability impact. | ||||