| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A missing authentication vulnerability in Palo Alto Networks Cortex XDR® Broker VM allows an unauthenticated user to disable certain internal services on the Broker VM.
The attacker must have network access to the Broker VM to exploit this issue. |
| Instantel Micromate lacks authentication on a configuration port which could allow an attacker to execute commands if connected. |
| An unauthenticated remote attacker can gain access to the cloud API due to a lack of authentication for a critical function in the affected devices. Availability is not affected. |
| A vulnerability has been identified in Perfect Harmony GH180 (All versions >= V8.0 < V8.3.3 with NXGPro+ controller manufactured between April 2020 to April 2025). The maintenance connection of affected devices fails to protect access to the device's control unit configuration. This could allow an attacker with physical access to the maintenance connection's door port to perform arbitrary configuration changes. |
| The web management interface of Okcat Parking Management Platform from ZONG YU has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to directly access system functions. These functions include opening gates, viewing license plates and parking records, and restarting the system. |
| A device takeover vulnerability exists in the Rockwell Automation Power Monitor 1000. This vulnerability allows configuration of a new Policyholder user without any authentication via API. Policyholder user is the most privileged user that can perform edit operations, creating admin users and performing factory reset. |
| A vulnerability allows unauthorized access to functionality inadequately constrained by ACLs. Attackers may exploit this to unauthenticated execute commands potentially leading to unauthorized data manipulation, access to privileged functions, or even the execution of arbitrary code. |
| A problem with missing authorization on SolaX Cloud platform allows taking over any SolaX solarpanel inverter of which the serial number is known. |
| Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web interface. An unauthenticated remote attacker can make changes to the system including: changing the web interface admin password, view/change system configuration, enumerate connected UPS devices and shut down connected UPS devices. This extends to being able to configure operating system commands that should run if the system detects a connected UPS shutting down. |
| The ASPECT system allows users to bypass authentication.
This issue affects all versions of ASPECT |
| A Missing Authentication for Critical Function vulnerability in the UniFi Connect EV Station Pro may allow a malicious actor with physical or adjacent access to perform an unauthorized factory reset.
Affected Products:
UniFi Connect EV Station Pro (Version 1.5.18 and earlier)
Mitigation:
Update UniFi Connect EV Station Pro to Version 1.5.27 or later |
| Missing Authentication for Critical Function vulnerability in the mobile monitoring feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric AnalytiX versions 10.97.2 and prior, Mitsubishi Electric MobileHMI versions 10.97.2 and prior, Mitsubishi Electric IoTWorX version 10.95, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.2 and prior, and Mitsubishi Electric Iconics Digital Solutions IoTWorX version 10.95 allows a remote unauthenticated attacker to bypass proper authentication and log in to the system when all of the following conditions are met: (1) Active Directory is used in the security setting (2) "Automatic log in" option is enabled in the security setting (3) The IcoAnyGlass IIS Application Pool is running under an Active Directory Domain Account. (4) The IcoAnyGlass IIS Application Pool account is included in GENESIS64, ICONCIS Suite, and MC Works64 Security and has permission to log in. |
| The web application allows an unauthenticated remote attacker to learn information about existing user accounts with their corresponding role due to missing authentication for critical function. |
| KuWFi CPF908-CP5 WEB5.0_LCD_20210125 devices have multiple unauthenticated access control vulnerabilities within goform/goform_set_cmd_process and goform/goform_get_cmd_process. These allow an unauthenticated attacker to retrieve sensitive information (including the device admin username and password), modify critical device settings, and send arbitrary SMS messages. |
| With address book access, SMB/FTP settings could be modified, redirecting scans and possibly capturing credentials. This requires enabled scan functions and printer access. |
| An issue in almaodo GmbH appinventor.ai_google.almando_control 2.3.1 allows a remote attacker to obtain sensitive information via the firmware update process |
| A Missing Authentication for Critical Function vulnerability in the GRUB configuration used B&R APROL <4.4-01 may allow an unauthenticated physical attacker to alter the boot configuration of the operating system. |
| Incorrect Implementation of Authentication Algorithm vulnerability in ABB WebPro SNMP Card PowerValue, ABB WebPro SNMP Card PowerValue UL.This issue affects WebPro SNMP Card PowerValue: through 1.1.8.K; WebPro SNMP Card PowerValue UL: through 1.1.8.K. |
| The vulnerability allows attackers access to the root account without having to authenticate. Specifically, if the device is configured with the IP address of 10.10.10.10, the root user is automatically logged in. |
| A vulnerability, which was classified as critical, has been found in IROAD Dash Cam X5 and Dash Cam X6 up to 20250308. Affected by this issue is some unknown functionality of the component API Endpoint. The manipulation leads to missing authentication. The attack may be launched remotely. The vendor was contacted early about this disclosure but did not respond in any way. |