Search Results (871 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-52284 1 Suse 1 Rancher 2026-04-15 7.7 High
Unauthorized disclosure of sensitive data: Any user with `GET` or `LIST` permissions on `BundleDeployment` resources could retrieve Helm values containing credentials or other secrets.
CVE-2024-47056 1 Mautic 1 Mautic 2026-04-15 5.1 Medium
SummaryThis advisory addresses a security vulnerability in Mautic where sensitive .env configuration files may be directly accessible via a web browser. This exposure could lead to the disclosure of sensitive information, including database credentials, API keys, and other critical system configurations. Sensitive Information Disclosure via .env File Exposure: The .env file, which typically contains environment variables and sensitive application configurations, is directly accessible via a web browser due to missing web server configurations that restrict access to such files. This allows an unauthenticated attacker to view the contents of this file by simply navigating to its URL. MitigationUpdate Mautic to the latest Mautic version. By default, Mautic does not use .env files for production data. For Apache users: Ensure your web server is configured to respect .htaccess files. For Nginx users: As Nginx does not inherently support .htaccess files, you must manually add a configuration block to your Nginx server configuration to deny access to .env files. Add the following to your Nginx configuration for the Mautic site: location ~ /\.env { deny all; } After modifying your Nginx configuration, remember to reload or restart your Nginx service for the changes to take effect.
CVE-2024-53651 2026-04-15 4.6 Medium
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions), SIPROTEC 5 6MD89 (CP300) (All versions), SIPROTEC 5 6MU85 (CP300) (All versions), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions), SIPROTEC 5 7SA82 (CP100) (All versions), SIPROTEC 5 7SA82 (CP150) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions), SIPROTEC 5 7SD82 (CP100) (All versions), SIPROTEC 5 7SD82 (CP150) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions), SIPROTEC 5 7SJ81 (CP100) (All versions), SIPROTEC 5 7SJ81 (CP150) (All versions), SIPROTEC 5 7SJ82 (CP100) (All versions), SIPROTEC 5 7SJ82 (CP150) (All versions), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions), SIPROTEC 5 7SK82 (CP100) (All versions), SIPROTEC 5 7SK82 (CP150) (All versions), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions), SIPROTEC 5 7SL82 (CP100) (All versions), SIPROTEC 5 7SL82 (CP150) (All versions), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions), SIPROTEC 5 7ST86 (CP300) (All versions), SIPROTEC 5 7SX82 (CP150) (All versions), SIPROTEC 5 7SX85 (CP300) (All versions), SIPROTEC 5 7SY82 (CP150) (All versions), SIPROTEC 5 7UM85 (CP300) (All versions), SIPROTEC 5 7UT82 (CP100) (All versions), SIPROTEC 5 7UT82 (CP150) (All versions), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions), SIPROTEC 5 7VE85 (CP300) (All versions), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions), SIPROTEC 5 7VU85 (CP300) (All versions), SIPROTEC 5 Compact 7SX800 (CP050) (All versions). Affected devices do not encrypt certain data within the on-board flash storage on their PCB. This could allow an attacker with physical access to read the entire filesystem of the device.
CVE-2024-4840 1 Redhat 1 Openstack 2026-04-15 5.5 Medium
An flaw was found in the OpenStack Platform (RHOSP) director, a toolset for installing and managing a complete RHOSP environment. Plaintext passwords may be stored in log files, which can expose sensitive information to anyone with access to the logs.
CVE-2024-8689 2026-04-15 N/A
A problem with the ActiveMQ integration for both Cortex XSOAR and Cortex XSIAM can result in the cleartext exposure of the configured ActiveMQ credentials in log bundles.
CVE-2025-55280 2026-04-15 N/A
This vulnerability exists in ZKTeco WL20 due to storage of Wi-Fi credentials, configuration data and system data in plaintext within the device firmware. An attacker with physical access could exploit this vulnerability by extracting the firmware and reverse engineer the binary data to access the plaintext sensitive data stored in the targeted device. Successful exploitation of this vulnerability could allow the attacker to gain unauthorized network access, retrieve and manipulate data on the targeted device.
CVE-2025-27532 2026-04-15 6.5 Medium
A vulnerability in the “Backup & Restore” functionality of the web application of ctrlX OS allows a remote authenticated (lowprivileged) attacker to access secret information via multiple crafted HTTP requests.
CVE-2024-39846 2026-04-15 3.5 Low
NewPass before 1.2.0 stores passwords (rather than password hashes) directly, which makes it easier to obtain unauthorized access to sensitive information. NOTE: in each case, data at rest is encrypted, but is decrypted within process memory during use.
CVE-2025-2189 2026-04-15 N/A
This vulnerability exists in the Tinxy smart devices due to storage of credentials in plaintext within the device firmware. An attacker with physical access could exploit this by extracting the firmware and analyzing the binary data to obtain the plaintext credentials stored on the vulnerable device.
CVE-2025-4394 2026-04-15 6.8 Medium
Medtronic MyCareLink Patient Monitor uses an unencrypted filesystem on internal storage, which allows an attacker with physical access to read and modify files. This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025
CVE-2023-28912 2026-04-15 5.7 Medium
The MIB3 unit stores the synchronized phone contact book in clear-text, allowing an attacker with either code execution privilege on the system or physical access to the system to obtain vehicle owner's contact data. The vulnerability was originally discovered in Skoda Superb III car with MIB3 infotainment unit OEM part number 3V0035820. The list of affected MIB3 OEM part numbers is provided in the referenced resources.
CVE-2024-45718 2026-04-15 4.6 Medium
Sensitive data could be exposed to non- privileged users in a configuration file. Local access to the computer with a low- privileged account is required to access the configuration file containing the sensitive data.
CVE-2025-6748 2026-04-15 2.1 Low
A vulnerability classified as problematic has been found in Bharti Airtel Thanks App 4.105.4 on Android. Affected is an unknown function of the file /Android/data/com.myairtelapp/files/. The manipulation leads to cleartext storage in a file or on disk. It is possible to launch the attack on the physical device. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-40753 1 Siemens 2 Q100, Q200 2026-04-15 6.2 Medium
A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q200 family (All versions >= V2.70 < V2.80). Affected devices export the password for the SMTP account as plain text in the Configuration File. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes.
CVE-2024-8070 2026-04-15 8.5 High
CWE-312: Cleartext Storage of Sensitive Information vulnerability exists that exposes test credentials in the firmware binary
CVE-2025-53755 2026-04-15 N/A
This vulnerability exists in Digisol DG-GR6821AC Router due to storage of credentials and PINS without encryption in the device firmware. An attacker with physical access could exploit this vulnerability by extracting the firmware and reverse engineer the binary data to access the unencrypted data stored in the firmware of targeted device. Successful exploitation of this vulnerability could allow the attacker to gain unauthorized access to the network of the targeted device.
CVE-2024-31486 2026-04-15 5.3 Medium
A vulnerability has been identified in OPUPI0 AMQP/MQTT (All versions < V5.30). The affected devices stores MQTT client passwords without sufficient protection on the devices. An attacker with remote shell access or physical access could retrieve the credentials leading to confidentiality loss.
CVE-2024-33470 2026-04-15 4.9 Medium
An issue in the SMTP Email Settings of AVTECH Room Alert 4E v4.4.0 allows attackers to gain access to credentials in plaintext via a passback attack. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.
CVE-2024-33471 2026-04-15 7.2 High
An issue in the Sensor Settings of AVTECH Room Alert 4E v4.4.0 allows attackers to gain access to SMTP credentials in plaintext via a crafted AJAX request. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.
CVE-2024-51175 2026-04-15 7.5 High
An issue in H3C switch h3c-S1526 allows a remote attacker to obtain sensitive information via the S1526.cfg component.