Search Results (729 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-1999-0007 5 C2net, Hp, Microsoft and 2 more 13 Stonghold Web Server, Open Market Secure Webserver, Exchange Server and 10 more 2026-04-16 N/A
Information from SSL-encrypted sessions via PKCS #1.
CVE-2025-65849 1 Altcha 1 Altcha 2026-04-15 9.1 Critical
A cryptanalytic break in Altcha Proof-of-Work obfuscation mode version 0.8.0 and later allows for remote visitors to recover the Proof-of-Work nonce in constant time via mathematical deduction. NOTE: this is disputed by the Supplier because the product's objective is "to discourage automated scraping / bots, not guarantee resistance to determined attackers." The documentation states “the goal is not to provide a secure cryptographic algorithm but to use a proof-of-work mechanism that allows any capable device to decrypt the hidden data.”
CVE-2025-51726 2026-04-15 8.4 High
CyberGhostVPNSetup.exe (Windows installer) is signed using the weak cryptographic hash algorithm SHA-1, which is vulnerable to collision attacks. This allows a malicious actor to craft a fake installer with a forged SHA-1 certificate that may still be accepted by Windows signature verification mechanisms, particularly on systems without strict SmartScreen or trust policy enforcement. Additionally, the installer lacks High Entropy Address Space Layout Randomization (ASLR), as confirmed by BinSkim (BA2015 rule) and repeated WinDbg analysis. The binary consistently loads into predictable memory ranges, increasing the success rate of memory corruption exploits. These two misconfigurations, when combined, significantly lower the bar for successful supply-chain style attacks or privilege escalation through fake installers.
CVE-2023-41928 2026-04-15 5.3 Medium
The device is observed to accept deprecated TLS protocols, increasing the risk of cryptographic weaknesses.
CVE-2025-2545 1 Best Practical Solutions 1 Request Tracker 2026-04-15 N/A
Vulnerability in Best Practical Solutions, LLC's Request Tracker prior to v5.0.8, where the Triple DES (3DES) cryptographic algorithm is used to protect emails sent with S/MIME encryption. Triple DES is considered obsolete and insecure due to its susceptibility to birthday attacks, which could compromise the confidentiality of encrypted messages.
CVE-2024-52801 2026-04-15 N/A
sftpgo is a full-featured and highly configurable event-driven file transfer solution. Server protocols: SFTP, HTTP/S, FTP/S, WebDAV. The OpenID Connect implementation allows authenticated users to brute force session cookies and thereby gain access to other users' data, since the cookies are generated predictably using the xid library and are therefore unique but not cryptographically secure. This issue was fixed in version v2.6.4, where cookies are opaque and cryptographically secure strings. All users are advised to upgrade. There are no known workarounds for this vulnerability.
CVE-2024-53441 2026-04-15 9.1 Critical
An issue in the index.js decryptCookie function of cookie-encrypter v1.0.1 allows attackers to execute a bit flipping attack.
CVE-2025-26708 2026-04-15 4.2 Medium
There is a configuration defect vulnerability in ZTELink 5.4.9 for iOS. This vulnerability is caused by a flaw in the WiFi parameter configuration of the ZTELink. An attacker can obtain unauthorized access to the WiFi service.
CVE-2025-27508 2026-04-15 7.5 High
Emissary is a P2P based data-driven workflow engine. The ChecksumCalculator class within allows for hashing and checksum generation, but it includes or defaults to algorithms that are no longer recommended for secure cryptographic use cases (e.g., SHA-1, CRC32, and SSDEEP). These algorithms, while possibly valid for certain non-security-critical tasks, can expose users to security risks if used in scenarios where strong cryptographic guarantees are required. This issue is fixed in 8.24.0.
CVE-2025-41223 2026-04-15 4.8 Medium
A vulnerability has been identified in RUGGEDCOM i800 (All versions), RUGGEDCOM i801 (All versions), RUGGEDCOM i802 (All versions), RUGGEDCOM i803 (All versions), RUGGEDCOM M2100 (All versions), RUGGEDCOM M2200 (All versions), RUGGEDCOM M969 (All versions), RUGGEDCOM RMC30 (All versions), RUGGEDCOM RMC8388 V4.X (All versions), RUGGEDCOM RMC8388 V5.X (All versions < V5.10.0), RUGGEDCOM RP110 (All versions), RUGGEDCOM RS1600 (All versions), RUGGEDCOM RS1600F (All versions), RUGGEDCOM RS1600T (All versions), RUGGEDCOM RS400 (All versions), RUGGEDCOM RS401 (All versions), RUGGEDCOM RS416 (All versions), RUGGEDCOM RS416P (All versions), RUGGEDCOM RS416Pv2 V4.X (All versions), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.10.0), RUGGEDCOM RS416v2 V4.X (All versions), RUGGEDCOM RS416v2 V5.X (All versions < V5.10.0), RUGGEDCOM RS8000 (All versions), RUGGEDCOM RS8000A (All versions), RUGGEDCOM RS8000H (All versions), RUGGEDCOM RS8000T (All versions), RUGGEDCOM RS900 (All versions), RUGGEDCOM RS900 (32M) V4.X (All versions), RUGGEDCOM RS900 (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RS900G (All versions), RUGGEDCOM RS900G (32M) V4.X (All versions), RUGGEDCOM RS900G (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RS900GP (All versions), RUGGEDCOM RS900L (All versions), RUGGEDCOM RS900M-GETS-C01 (All versions), RUGGEDCOM RS900M-GETS-XX (All versions), RUGGEDCOM RS900M-STND-C01 (All versions), RUGGEDCOM RS900M-STND-XX (All versions), RUGGEDCOM RS900W (All versions), RUGGEDCOM RS910 (All versions), RUGGEDCOM RS910L (All versions), RUGGEDCOM RS910W (All versions), RUGGEDCOM RS920L (All versions), RUGGEDCOM RS920W (All versions), RUGGEDCOM RS930L (All versions), RUGGEDCOM RS930W (All versions), RUGGEDCOM RS940G (All versions), RUGGEDCOM RS969 (All versions), RUGGEDCOM RSG2100 (All versions), RUGGEDCOM RSG2100 (32M) V4.X (All versions), RUGGEDCOM RSG2100 (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RSG2100P (All versions), RUGGEDCOM RSG2100P (32M) V4.X (All versions), RUGGEDCOM RSG2100P (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RSG2200 (All versions), RUGGEDCOM RSG2288 V4.X (All versions), RUGGEDCOM RSG2288 V5.X (All versions < V5.10.0), RUGGEDCOM RSG2300 V4.X (All versions), RUGGEDCOM RSG2300 V5.X (All versions < V5.10.0), RUGGEDCOM RSG2300P V4.X (All versions), RUGGEDCOM RSG2300P V5.X (All versions < V5.10.0), RUGGEDCOM RSG2488 V4.X (All versions), RUGGEDCOM RSG2488 V5.X (All versions < V5.10.0), RUGGEDCOM RSG907R (All versions < V5.10.0), RUGGEDCOM RSG908C (All versions < V5.10.0), RUGGEDCOM RSG909R (All versions < V5.10.0), RUGGEDCOM RSG910C (All versions < V5.10.0), RUGGEDCOM RSG920P V4.X (All versions), RUGGEDCOM RSG920P V5.X (All versions < V5.10.0), RUGGEDCOM RSL910 (All versions < V5.10.0), RUGGEDCOM RST2228 (All versions < V5.10.0), RUGGEDCOM RST2228P (All versions < V5.10.0), RUGGEDCOM RST916C (All versions < V5.10.0), RUGGEDCOM RST916P (All versions < V5.10.0). The affected devices support the TLS_ECDHE_ECDSA_WITH_AES_128_CBC_SHA256 cipher suite, which uses CBC (Cipher Block Chaining) mode that is known to be vulnerable to timing attacks. This could allow an attacker to compromise the integrity and confidentiality of encrypted communications.
CVE-2024-36440 1 Swissphone 1 Dical-red 2026-04-15 6.8 Medium
An issue was discovered on Swissphone DiCal-RED 4009 devices. An attacker with access to the file /etc/deviceconfig may recover the administrative device password via password-cracking methods, because unsalted MD5 is used.
CVE-2025-14759 1 Amazon 1 Aws S3 Encryption Client Dotnet 2026-04-15 5.3 Medium
Missing cryptographic key commitment in the Amazon S3 Encryption Client for .NET may allow a user with write access to the S3 bucket to introduce a new EDK that decrypts to different plaintext when the encrypted data key is stored in an "instruction file" instead of S3's metadata record. To mitigate this issue, upgrade Amazon S3 Encryption Client for .NET to version 3.2.0 or later.
CVE-2025-7214 1 Fnkvision 1 Fnk-gu2 2026-04-15 1.6 Low
A vulnerability classified as problematic was found in FNKvision FNK-GU2 up to 40.1.7. Affected by this vulnerability is an unknown functionality of the file /etc/shadow of the component MD5. The manipulation leads to risky cryptographic algorithm. It is possible to launch the attack on the physical device. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used.
CVE-2025-2920 2026-04-15 2 Low
A vulnerability was found in Netis WF-2404 1.1.124EN. It has been rated as problematic. This issue affects some unknown processing of the file /еtc/passwd. The manipulation leads to use of weak hash. It is possible to launch the attack on the physical device. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-37127 2 Arubanetworks, Hp 2 Edgeconnect Enterprise, Arubaos 2026-04-15 7.2 High
A vulnerability in the cryptographic logic used by HPE Aruba Networking EdgeConnect SD-WAN Gateways could allow an authenticated remote attacker to gain shell access. Successful exploitation could allow an attacker to execute arbitrary commands on the underlying operating system, potentially leading to unauthorized access and control over the affected systems.
CVE-2023-41927 2026-04-15 5.3 Medium
The server supports at least one cipher suite which is on the NCSC-NL list of cipher suites to be phased out, increasing the risk of cryptographic weaknesses.
CVE-2025-9383 1 Fnkvision 1 Y215 Cctv Camera 2026-04-15 2.5 Low
A security vulnerability has been detected in FNKvision Y215 CCTV Camera 10.194.120.40. This issue affects the function crypt of the file /etc/passwd. The manipulation leads to use of weak hash. The attack can only be performed from a local environment. The complexity of an attack is rather high. The exploitability is assessed as difficult. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-59484 1 Automationdirect 1 Click Plus 2026-04-15 8.3 High
The use of a broken or risky cryptographic algorithm was discovered in firmware version 3.60 of the Click Plus PLC. The vulnerability relies on the fact that the software uses an insecure implementation of the RSA encryption algorithm.
CVE-2025-45764 2026-04-15 3.2 Low
jsrsasign v11.1.0 was discovered to contain weak encryption. NOTE: this issue has been disputed by a third party who believes that CVE IDs can be assigned for key lengths in specific applications that use a library, and should not be assigned to the default key lengths in a library. This dispute is subject to review under CNA rules 4.1.4, 4.1.14, and other rules; the dispute tagging is not meant to recommend an outcome for this CVE Record.
CVE-2025-7071 2026-04-15 N/A
Padding oracle attack vulnerability in Oberon microsystem AG’s ocrypto library in all versions since 3.1.0 and prior to 3.9.2 allows an attacker to recover plaintexts via timing measurements of AES-CBC PKCS#7 decrypt operations.