| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Sensitive data disclosure and manipulation due to missing authentication. The following products are affected: Acronis Cyber Protect Cloud Agent (Linux, macOS, Windows) before build 39870, Acronis Cyber Protect 16 (Linux, macOS, Windows) before build 39938, Acronis Cyber Protect 15 (Linux, macOS, Windows) before build 41800. |
| A state machine transition flaw in the Bluetooth Low Energy (BLE) stack of Cypress PSoC4 v3.66 allows attackers to bypass the pairing process and authentication via a crafted pairing_failed packet. |
| An authenticated command injection vulnerability exists in OP5 Monitor through version 7.1.9 via the 'cmd_str' parameter in the command_test.php endpoint. A user with access to the web interface can exploit the 'Test this command' feature to execute arbitrary shell commands as the unprivileged web application user. The vulnerability resides in the configuration section of the application and requires valid login credentials with access to the command testing functionality. This issue is fixed in version 7.2.0. |
| An authenticated multi-stage remote code execution vulnerability exists in Riverbed SteelCentral NetProfiler and NetExpress 10.8.7 virtual appliances. A SQL injection vulnerability in the '/api/common/1.0/login' endpoint can be exploited to create a new user account in the appliance database. This user can then trigger a command injection vulnerability in the '/index.php?page=licenses' endpoint to execute arbitrary commands. The attacker may escalate privileges to root by exploiting an insecure sudoers configuration that allows the 'mazu' user to execute arbitrary commands as root via SSH key extraction and command chaining. Successful exploitation allows full remote root access to the virtual appliance. |
| An unrestricted file upload vulnerability exists in BuilderEngine 3.5.0 via the integration of the elFinder 2.0 file manager and its use of the jQuery File Upload plugin. The plugin fails to properly validate or restrict file types or locations during upload operations, allowing an attacker to upload a malicious .php file and subsequently execute arbitrary PHP code on the server under the context of the web server process. While the root vulnerability lies within the jQuery File Upload component, BuilderEngine’s improper integration and lack of access controls expose this functionality to unauthenticated users, resulting in full remote code execution. |
| COMMAX Smart Home System allows an unauthenticated attacker to change configuration and cause denial-of-service through the setconf endpoint. Attackers can trigger a denial-of-service scenario by sending a malformed request to the setconf endpoint. |
| NVIDIA Isaac Lab contains a vulnerability in SB3 configuration parsing. A successful exploit of this vulnerability might lead to code execution, denial of service, escalation of privileges, information disclosure, or data tampering. |
| The MinigameCenter module has insufficient restrictions on loading URLs, which may lead to some information leakage. |
| An issue in Plug n Play Camera com.ezset.delaney 1.2.0 allows a remote attacker to obtain sensitive information via the firmware update process. |
| An issue was discovered on Marbella KR8s Dashcam FF 2.0.8 devices. Via port 7777 without any need to pair or press a physical button, a remote attacker can disable recording, delete recordings, or even disable battery protection to cause a flat battery to essentially disable the car from being used. During the process of changing these settings, there are no indications or sounds on the dashcam to alert the dashcam owner that someone else is making those changes. |
| Toshiba printers provides API without authentication for internal access. A local attacker can bypass authentication in applications, providing administrative access. As for the affected products/models/versions, see the reference URL. |
| EasyFlow .NET and EasyFlow AiNet, developed by Digiwin, has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to obtain database administrator credentials via a specific functionality. |
| There is a misconfiguration vulnerability inside the Infotainment ECU manufactured by BOSCH. The vulnerability happens during the startup phase of a specific systemd service, and as a result, the following developer features will be activated: the disabled firewall and the launched SSH server.
First identified on Nissan Leaf ZE1 manufactured in 2020. |
| A flaw was found in dogtag-pki and pki-core. The token authentication scheme can be bypassed with a LDAP injection. By passing the query string parameter sessionID=*, an attacker can authenticate with an existing session saved in the LDAP directory server, which may lead to escalation of privilege. |
| Seeyon Zhiyuan OA Web Application System versions up to and including 7.0 SP1Â improperly decode and parse the `enc` parameter in thirdpartyController.do. The decoded map values can influence session attributes without sufficient authentication/authorization checks, enabling attackers to assign a session to arbitrary user IDs. VulnCheck has observed this vulnerability being exploited in the wild as of 2025-10-30 at 00:30:40.855917 UTC. |
| The Linux Kernel lockdown mode for kernel versions starting on 6.12 and above for Fedora Linux has the lockdown mode disabled without any warning. This may allow an attacker to gain access to sensitive information such kernel memory mappings, I/O ports, BPF and kprobes. Additionally unsigned modules can be loaded, leading to execution of untrusted code breaking breaking any Secure Boot protection. This vulnerability affects only Fedora Linux. |
| The affected product is vulnerable to an attacker being able to use commands without providing a password which may allow an attacker to leak information. |
| In RPyC before 6.0.0, when a server exposes a method that calls the attribute named __array__ for a client-provided netref (e.g., np.array(client_netref)), a remote attacker can craft a class that results in remote code execution. |
| Incorrect access control in the component l_0_0.xml of TP-Link ARCHER-C7 v5 allows attackers to access sensitive information. |
| A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to manipulate the devices IP address, which means the device would not be reachable. |