| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An insecure deserialization vulnerability exists in the BentoML framework, allowing remote code execution (RCE) by sending a specially crafted POST request. By exploiting this vulnerability, attackers can execute arbitrary commands on the server hosting the BentoML application. The vulnerability is triggered when a serialized object, crafted to execute OS commands upon deserialization, is sent to any valid BentoML endpoint. This issue poses a significant security risk, enabling attackers to compromise the server and potentially gain unauthorized access or control. |
| The exos 9300 application can be used to configure Access Managers (e.g. 92xx, 9230 and 9290). The configuration is done in a graphical user interface on the dormakaba exos server. As soon as the save button is clicked in exos 9300, the whole configuration is sent to the selected Access Manager via SOAP. The SOAP request is sent without any prior authentication or authorization by default. Though authentication and authorization can be configured using IPsec for 92xx-K5 devices and mTLS for 92xx-K7 devices, it is not enabled by default and must therefore be activated with additional steps.
This insecure default allows an attacker with network level access to completely control the whole environment. An attacker is for example easily able to conduct the following tasks without prior authentication:
- Re-configure Access Managers (e.g. remove alarming system requirements)
- Freely re-configure the inputs and outputs
- Open all connected doors permanently
- Open all doors for a defined time interval
- Change the admin password
- and many more
Network level access can be gained due to an insufficient network segmentation as well as missing LAN firewalls. Devices with an insecure configuration have been identified to be directly exposed to the internet. |
| vodozemac is an implementation of Olm and Megolm in pure Rust. Versions 0.5.0 and 0.5.1 of vodozemac have degraded secret zeroization capabilities, due to changes in third-party cryptographic dependencies (the Dalek crates), which moved secret zeroization capabilities behind a feature flag and defaulted this feature to off. The degraded zeroization capabilities could result in the production of more memory copies of encryption secrets and secrets could linger in memory longer than necessary. This marginally increases the risk of sensitive data exposure. This issue has been addressed in version 0.6.0 and users are advised to upgrade. There are no known workarounds for this vulnerability. |
| Zipkin through 3.5.1 has a /heapdump endpoint (associated with the use of Spring Boot Actuator), a similar issue to CVE-2025-48927. |
| Initialization of a resource with an insecure default vulnerability exists in JavaTM Platform Ver.12.89 and earlier. If this vulnerability is exploited, the product may be affected by some known TLS1.0 and TLS1.1 vulnerabilities. As for the specific products/models/versions of MFPs and printers that contain JavaTM Platform, see the information provided by the vendor. |
| Improper isolation in the Intel(R) Core(TM) Ultra Processor stream cache mechanism may allow an authenticated user to potentially enable escalation of privilege via local access. |
| The CS5000 Fire Panel is vulnerable due to a default account that exists
on the panel. Even though it is possible to change this by SSHing into
the device, it has remained unchanged on every installed system
observed. This account is not root but holds high-level permissions that
could severely impact the device's operation if exploited. |
| Enabled IP Forwarding feature in B&R Automation Runtime versions before 6.0.2 may allow remote attack-ers to compromise network security by routing IP-based packets through the host, potentially by-passing firewall, router, or NAC filtering. |
| An Exposure of Sensitive System Information to an Unauthorized Control Sphere and Initialization of a Resource with an Insecure Default vulnerability in the SNMP component of B&R APROL <4.4-00P5 may allow an unauthenticated adjacent-based attacker to read and alter configuration using SNMP. |
| Insecure default settings have been found in recorder products provided by Yokogawa Electric Corporation. The default setting of the authentication function is disabled on the affected products. Therefore, when connected to a network with default settings, anyone can access all functions related to settings and operations. As a result, an attacker can illegally manipulate and configure important data such as measured values and settings.
This issue affects GX10 / GX20 / GP10 / GP20 Paperless Recorders: R5.04.01 or earlier; GM Data Acquisition System: R5.05.01 or earlier; DX1000 / DX2000 / DX1000N Paperless Recorders: R4.21 or earlier; FX1000 Paperless Recorders: R1.31 or earlier; μR10000 / μR20000 Chart Recorders: R1.51 or earlier; MW100 Data Acquisition Units: All versions; DX1000T / DX2000T Paperless Recorders: All versions; CX1000 / CX2000 Paperless Recorders: All versions. |
| During a short time frame while the device is booting an unauthenticated remote attacker can send traffic to unauthorized networks due to the switch operating in an undefined state until a CPU-induced reset allows proper configuration. |
| Incorrect configuration of replication security in the MariaDB component of the infra-operator in YAOOK Operator allows an on-path attacker to read database contents, potentially including credentials |
| The Versa Director software exposes a number of services by default and allow attackers an easy foothold due to default credentials and multiple accounts (most with sudo access) that utilize the same default credentials. By default, Versa director exposes ssh and postgres to the internet, alongside a host of other services.
Versa Networks is not aware of any reported instance where this vulnerability was exploited. Proof of concept for this vulnerability has been disclosed by third party security researchers.
Workarounds or Mitigation:
Versa recommends the following security controls:
1) Change default passwords to complex passwords
2) Passwords must be complex with at least 8 characters that comprise of upper case, and lower case alphabets, as well as at at least one digit, and one special character
3) Passwords must be changed at least every 90 days
4) Password change history is checked to ensure that the at least the last 5 passwords must be used when changing password.
5) Review and audit logs for all authentication attempts to check for unauthorized/suspicious login attempts and enforce remediation steps. |
| The BigFix SaaS's HTTP responses were missing some security headers. The absence of these headers weakens the application's client-side security posture, making it more vulnerable to common web attacks that these headers are designed to mitigate, such as Cross-Site Scripting (XSS), Clickjacking, and protocol downgrade attacks. |
| Improper isolation of shared resources on a system on a chip by a malicious local attacker with high privileges could potentially lead to a partial loss of integrity. |
| An issue in MikroTik RouterOS v.7.14.2 and SwOS v.2.18 exposes the WebFig management interface over cleartext HTTP by default, allowing an on-path attacker to execute injected JavaScript in the administrator’s browser and intercept credentials. |
| CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could potentially lead to
unauthorized access which could result in the loss of confidentially, integrity and availability when a malicious
user, having physical access, sets the radio to the factory default mode. |
| Himmelblau is an interoperability suite for Microsoft Azure Entra ID and Intune. Himmelblau 0.9.x derives numeric GIDs for Entra ID groups from the group display name when himmelblau.conf `id_attr_map = name` (the default configuration). Because Microsoft Entra ID allows multiple groups with the same `displayName` (including end-user–created personal/O365 groups, depending on tenant policy), distinct directory groups can collapse to the same numeric GID on Linux. This issue only applies to Himmelblau versions 0.9.0 through 0.9.22. Any resource or service on a Himmelblau-joined host that enforces authorization by numeric GID (files/dirs, etc.) can be unintentionally accessible to a user who creates or joins a different Entra/O365 group that happens to share the same `displayName` as a privileged security group. Users should upgrade to 0.9.23, or 1.0.0 or later, to receive a patch. Group to GID mapping now uses Entra ID object IDs (GUIDs) and does not collide on same-name groups. As a workaround, use tenant policy hardening to restrict arbitrary group creation until all hosts are patched. |
| Asio C++ Library before 1.13.0 lacks a fallback error code in the case of SSL_ERROR_SYSCALL with no associated error information from the SSL library being used. |
| CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could lead to loss of
confidentiality when a malicious user, having physical access, sets the radio in factory default mode where the
product does not correctly initialize all data. |