| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A vulnerability has been identified in Industrial Edge Management Pro (All versions < V1.9.5), Industrial Edge Management Virtual (All versions < V2.3.1-1). Affected components do not properly validate the device tokens. This could allow an unauthenticated remote attacker to impersonate other devices onboarded to the system. |
| The web application uses a weak authentication mechanism to verify that a request is coming from an authenticated and authorized resource. |
| An OS Command Injection vulnerability exists within myPRO Manager. A parameter within a command can be exploited by an unauthenticated remote attacker to inject arbitrary operating system commands. |
| A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions < V2020 SP2 Update 5), SIMATIC Information Server 2022 (All versions < V2022 SP1 Update 2), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC06), SIMATIC Process Historian 2020 (All versions < V2020 SP2 Update 5), SIMATIC Process Historian 2022 (All versions < V2022 SP1 Update 2), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 5), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 3), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 18), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5). The affected products run their DB server with elevated privileges which could allow an authenticated attacker to execute arbitrary OS commands with administrative privileges. |
| A vulnerability has been identified in Opcenter Quality (All versions < V2406), Opcenter RDnL (All versions < V2410), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 2), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SINEC NMS (All versions), SINEMA Remote Connect Client (All versions < V3.2 SP3), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 5), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 3). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code. |
| Heatmiser Netmonitor 3.03 contains a hardcoded credentials vulnerability in the networkSetup.htm page with predictable admin login credentials. Attackers can access the device by using the hard-coded username 'admin' and password 'admin' in the hidden form input fields. |
| A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). The affected application assigns incorrect permissions to a user management component. This could allow a privileged attacker to escalate their privileges from the Administrators group to the Systemadministrator group. |
| A SQL injection vulnerability has been identified in DobryCMS. Improper neutralization of input provided by user into language functionality allows for SQL Injection attacks.
This issue affects older branches of this software. |
| A command injection vulnerability exists in the eScan Web Management Console version 5.5-2. The application fails to properly sanitize the 'pass' parameter when processing login requests to login.php, allowing an authenticated attacker with a valid username to inject arbitrary commands via a specially crafted password value. Successful exploitation results in remote code execution. Privilege escalation to root is possible by abusing the runasroot utility with mwconf-level privileges. |
| In versions of Zend Server 8.5 and prior to version 9.2 a format string injection was discovered.
Reported by Dylan Marino |
| A Remote Code Execution Vulnerability exists in the product and version listed above. The vulnerability is due to lack of input sanitation and could allow a remote attacker to run commands or code as a high privileged user. |
| KUNBUS Revolution Pi OS Bookworm 01/2025 is vulnerable because authentication is not configured by default for the Node-RED server. This can give an unauthenticated remote attacker full access to the Node-RED server where they can run arbitrary commands on the underlying operating system. |
| Missing Authentication for Critical Function vulnerability in ABB ALS-mini-s4 IP, ABB ALS-mini-s8 IP.This issue affects .
All firmware versions with the Serial Number from 2000 to 5166 |
| A malicious actor can fix the session of a PAM user by tricking the user to click on a specially crafted link to the PAM server. |
| An OS command injection vulnerability exists in sar2html version 3.2.2 and prior via the plot parameter in index.php. The application fails to sanitize user-supplied input before using it in a system-level context. Remote, unauthenticated attackers can inject shell commands by appending them to the plot parameter (e.g., ?plot=;id) in a crafted GET request. The output of the command is displayed in the application's interface after interacting with the host selection UI. Successful exploitation leads to arbitrary command execution on the underlying system. Exploitation evidence was observed by the Shadowserver Foundation on 2025-02-04 UTC. |
| GeoVision embedded IP devices, confirmed on GV-BX1500 and GV-MFD1501, contain a remote command injection vulnerability via /PictureCatch.cgi that enables an attacker to execute arbitrary commands on the device. The vulnerable models have been declared end-of-life (EOL) by the vendor. VulnCheck has observed this vulnerability being exploited in the wild as of 2025-10-19 08:55:13.141502 UTC. |
| Remote attackers can execute arbitrary code in the context of the vulnerable service process. |
| Improper input validation in the Linux kernel-mode driver for some Intel(R) 800 Series Ethernet before version 1.17.2 may allow an authenticated user to potentially enable escalation of privilege via local access. |
| A PHP object injection vulnerability exists in SugarCRM versions prior to 6.5.24, 6.7.13, 7.5.2.5, 7.6.2.2, and 7.7.1.0 due to improper validation of PHP serialized input in the SugarRestSerialize.php script. The vulnerable code fails to sanitize the rest_data parameter before passing it to the unserialize() function. This allows an unauthenticated attacker to submit crafted serialized data containing malicious object declarations, resulting in arbitrary code execution within the application context. Although SugarCRM released a prior fix in advisory sugarcrm-sa-2016-001, the patch was incomplete and failed to address some vectors. Exploitation evidence was observed by the Shadowserver Foundation on 2024-09-13 UTC. |
| A remote command injection vulnerability exists in the confirm.php interface of the WIFISKY 7-layer Flow Control Router via a specially-crafted HTTP GET request to the t parameter. Insufficient input validation allows unauthenticated attackers to execute arbitrary OS commands. Exploitation evidence was observed by the Shadowserver Foundation on 2025-01-25 UTC. |