| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Ash Authentication provides authentication for the Ash framework. The confirmation flow for account creation currently uses a GET request triggered by clicking a link sent via email. Some email clients and security tools (e.g., Outlook, virus scanners, and email previewers) may automatically follow these links, unintentionally confirming the account. This allows an attacker to register an account using another user’s email and potentially have it auto-confirmed by the victim’s email client. This does not allow attackers to take over or access existing accounts or private data. It is limited to account confirmation of new accounts only. This vulnerability is fixed in 4.7.0. |
| Improper Authentication vulnerability in Danfoss AKSM8xxA Series.This issue affects Danfoss AK-SM 8xxA Series prior to version 4.2 |
| An unauthenticated remote attacker can run arbitrary commands on the affected devices with high privileges because the authentication for the Node_RED server is not configured by default. |
| Spring Security Aspects may not correctly locate method security annotations on private methods. This can cause an authorization bypass.
Your application may be affected by this if the following are true:
* You are using @EnableMethodSecurity(mode=ASPECTJ) and spring-security-aspects, and
* You have Spring Security method annotations on a private method
In that case, the target method may be able to be invoked without proper authorization.
You are not affected if:
* You are not using @EnableMethodSecurity(mode=ASPECTJ) or spring-security-aspects, or
* You have no Spring Security-annotated private methods |
| OPW Fuel Management Systems SiteSentinel
could allow an attacker to bypass authentication to the server and obtain full admin privileges. |
| RatPanel is a server operation and maintenance management panel. In versions 2.3.19 through 2.5.5, when an attacker obtains the backend login path of RatPanel (including but not limited to weak default paths, brute-force cracking, etc.), they can execute system commands or take over hosts managed by the panel without logging in. In addition to this remote code execution (RCE) vulnerability, the flawed code also leads to unauthorized access. RatPanel uses the CleanPath middleware provided by github.com/go-chi/chi package to clean URLs, but but the middleware does not process r.URL.Path, which can cause the paths to be misinterpreted. This is fixed in version 2.5.6. |
| The endpoint hosts a script that allows an unauthorized remote attacker to put the system in a fail-safe state over the network due to missing authentication. |
| A vulnerability was found in Windmill 1.380.0. It has been classified as problematic. Affected is an unknown function of the file backend/windmill-api/src/users.rs of the component HTTP Request Handler. The manipulation leads to improper restriction of excessive authentication attempts. It is possible to launch the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. Upgrading to version 1.390.1 is able to address this issue. The patch is identified as acfe7786152f036f2476f93ab5536571514fa9e3. It is recommended to upgrade the affected component. |
| The privileged user could log in without sufficient credentials after enabling an application protocol. This security issue has been fixed in the latest script patch latest version of of Eaton BLSS (7.3.0.SCP004). |
| There is no limit on the number of failed login attempts permitted with the Clinician Password or the Serial Number Clinician Password. An attacker could execute a brute-force attack to gain unauthorized access to the ventilator, and then make changes to device settings that could disrupt the function of the device and/or result in unauthorized information disclosure. |
| A vulnerability in Kaiten version 57.131.12 and earlier allows attackers to bypass the PIN code authentication mechanism. The application requires users to input a 6-digit PIN code sent to their email for authorization after entering their login credentials. However, the request limiting mechanism can be easily bypassed, enabling attackers to perform a brute force attack to guess the correct PIN and gain unauthorized access to the application. |
| The Archify application contains a local privilege escalation vulnerability due to insufficient client validation in its privileged helper tool, com.oct4pie.archifyhelper, which is exposed via XPC. Archify follows the "factored applications" model, delegating privileged operations—such as arbitrary file deletion and file permission changes—to this helper running as root. However, the helper does not verify the code signature, entitlements, or signing flags of the connecting client. Although macOS provides secure validation mechanisms like auditToken, these are not implemented. As a result, any local process can establish a connection to the helper and invoke privileged functionality, leading to unauthorized execution of actions with root-level privileges. |
| Simofa is a tool to help automate static website building and deployment. Prior to version 0.2.7, due to a design mistake in the RouteLoader class, some API routes may be publicly accessible when they should require authentication. This vulnerability has been patched in v0.2.7. |
| The Get Quote For Woocommerce – Request A Quote For Woocommerce plugin for WordPress is vulnerable to unauthorized access of Quote data due to a missing capability check on the ct_tepfw_wp_loaded function in all versions up to, and including, 1.0.0. This makes it possible for unauthenticated attackers to download Quote PDF and CSV documents. |
| An unauthenticated remote attacker can obtain limited sensitive information and/or DoS the device due to missing authentication for critical function. |
| The administrative interface listens by default on all interfaces on a TCP port and does not require authentication when being accessed. |
| An improper exception check in Palo Alto Networks Prisma Access Browser allows a low privileged user to prevent Prisma Access Browser from applying it's Policy Rules. This enables the user to use Prisma Access Browser without any restrictions. |
| Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series CPU module allows a remote unauthenticated attacker to read or write the device values of the product and stop the operation of the programs, since MODBUS/TCP in the products does not have authentication features. |
| A unauthorized access vulnerability exists in the Xiaomi phone framework. The vulnerability is caused by improper validation and can be exploited by attackers to Access sensitive methods. |
| Incorrect Implementation of Authentication Algorithm vulnerability in ABB ABB Ability OPTIMAX.This issue affects ABB Ability OPTIMAX: 6.1, 6.2, from 6.3.0 before 6.3.1-251120, from 6.4.0 before 6.4.1-251120. |