Search Results (226 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-9574 1 Abb 2 Als-mini-s4, Als-mini-s8 2026-04-15 10 Critical
Missing Authentication for Critical Function vulnerability in ABB ALS-mini-s4 IP, ABB ALS-mini-s8 IP.This issue affects .  All firmware versions with the Serial Number from 2000 to 5166
CVE-2025-5517 1 Abb 8 Terra Ac Wallbox Ce Juno, Terra Ac Wallbox Ce Juno Firmware, Terra Ac Wallbox Ce Mid and 5 more 2026-04-15 6.8 Medium
Heap-based Buffer Overflow vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (MID/ CE) -Terra AC MID, ABB Terra AC wallbox (MID/ CE) -Terra AC Juno CE, ABB Terra AC wallbox (MID/ CE) -Terra AC PTB, ABB Terra AC wallbox (JP).This issue affects Terra AC wallbox (UL40/80A): through 1.8.32; Terra AC wallbox (UL32A): through 1.8.2; Terra AC wallbox (MID/ CE) -Terra AC MID: through 1.8.32; Terra AC wallbox (MID/ CE) -Terra AC Juno CE: through 1.8.32; Terra AC wallbox (MID/ CE) -Terra AC PTB: through 1.8.21; Terra AC wallbox (JP): through 1.8.2.
CVE-2024-13949 1 Abb 3 Aspect Enterprise, Matrix Series, Nexus Series 2026-04-15 6.8 Medium
Large content vulnerabilities are present in ASPECT exposing a device to disk overutilization on a system if administrator credentials become compromisedThis issue affects ASPECT-Enterprise: through 3.*; NEXUS Series: through 3.*; MATRIX Series: through 3.*.
CVE-2025-4676 1 Abb 2 Webpro Snmp Card Powervalue, Webpro Snmp Card Powervalue Ul 2026-04-15 8.8 High
Incorrect Implementation of Authentication Algorithm vulnerability in ABB WebPro SNMP Card PowerValue, ABB WebPro SNMP Card PowerValue UL.This issue affects WebPro SNMP Card PowerValue: through 1.1.8.K; WebPro SNMP Card PowerValue UL: through 1.1.8.K.
CVE-2025-10205 1 Abb 1 Flxeon 2026-04-15 8.8 High
Use of a One-Way Hash with a Predictable Salt vulnerability in ABB FLXEON.This issue affects FLXEON: through 9.3.5. and newer versions
CVE-2025-13777 1 Abb 2 Awin Gw100 Rev.2, Awin Gw120 2026-03-23 8.3 High
Authentication bypass by capture-replay vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.This issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1.
CVE-2025-13778 1 Abb 2 Awin Gw100 Rev.2, Awin Gw120 2026-03-23 6.5 Medium
Missing authentication for critical function vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.This issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1.
CVE-2025-13779 1 Abb 2 Awin Gw100 Rev.2, Awin Gw120 2026-03-23 8.3 High
Missing authentication for critical function vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.This issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1.
CVE-2024-3036 1 Abb 1 800xa Base System 2025-12-19 5.7 Medium
Improper Input Validation vulnerability in ABB 800xA Base. An attacker who successfully exploited this vulnerability could cause services to crash by sending specifically crafted messages. This issue affects 800xA Base: from 6.0.0 through 6.1.1-2.
CVE-2024-4007 1 Abb 26 Aspect-ent-12, Aspect-ent-12 Firmware, Aspect-ent-2 and 23 more 2025-12-19 8.8 High
Default credential in install package in ABB ASPECT; NEXUS Series; MATRIX Series version 3.07 allows attacker to login to product instances wrongly configured.
CVE-2020-11639 1 Abb 1 Advabuild 2025-12-19 7.8 High
An attacker could exploit the vulnerability by injecting garbage data or specially crafted data. Depending on the data injected each process might be affected differently. The process could crash or cause communication issues on the affected node, effectively causing a denial-of-service attack. The attacker could tamper with the data transmitted, causing the product to store wrong information or act on wrong data or display wrong information. This issue affects Advant MOD 300 AdvaBuild: from 3.0 through 3.7 SP2. For an attack to be successful, the attacker must have local access to a node in the system and be able to start a specially crafted application that disrupts the communication. An attacker who successfully exploited the vulnerability would be able to manipulate the data in such way as allowing reads and writes to the controllers or cause Windows processes in 800xA for MOD 300 and AdvaBuild to crash.
CVE-2020-11640 1 Abb 1 Advabuild 2025-12-19 8.8 High
AdvaBuild uses a command queue to launch certain operations. An attacker who gains access to the command queue can use it to launch an attack by running any executable on the AdvaBuild node. The executables that can be run are not limited to AdvaBuild specific executables.  Improper Privilege Management vulnerability in ABB Advant MOD 300 AdvaBuild.This issue affects Advant MOD 300 AdvaBuild: from 3.0 through 3.7 SP2.
CVE-2024-1914 1 Abb 7 Irc5, Omnicore C30, Omnicore C90xt and 4 more 2025-12-19 6.5 Medium
An attacker who successfully exploited these vulnerabilities could cause the robot to stop, make the robot controller inaccessible. The vulnerability could potentially be exploited to perform unauthorized actions by an attacker. This vulnerability arises under specific condition when specially crafted message is processed by the system. Below are reported vulnerabilities in the Robot Ware versions. * IRC5- RobotWare 6 < 6.15.06 except 6.10.10, and 6.13.07 * OmniCore- RobotWare 7 < 7.14
CVE-2024-1913 1 Abb 7 Irc5, Omnicore C30, Omnicore C90xt and 4 more 2025-12-19 7.6 High
An attacker who successfully exploited these vulnerabilities could cause the robot to stop, make the robot controller inaccessible, or execute arbitrary code.  The vulnerability could potentially be exploited to perform unauthorized actions by an attacker. This vulnerability arises under specific condition when specially crafted message is processed by the system. Below are reported vulnerabilities in the Robot Ware versions. * IRC5- RobotWare 6 < 6.15.06 except 6.10.10, and 6.13.07 * OmniCore- RobotWare 7 < 7.14
CVE-2024-4008 1 Abb 10 2tma310010b0001, 2tma310010b0001 Firmware, 2tma310010b0003 and 7 more 2025-09-17 9.6 Critical
FDSK Leak in ABB, Busch-Jaeger, FTS Display (version 1.00) and BCU (version 1.3.0.33) allows attacker to take control via access to local KNX Bus-System
CVE-2025-53191 1 Abb 3 Aspect Enterprise, Matrix Series, Nexus Series 2025-08-21 N/A
This CVE ID has been rejected or withdrawn by its CVE Numbering Authority.
CVE-2025-53190 1 Abb 3 Aspect Enterprise, Matrix Series, Nexus Series 2025-08-21 N/A
This CVE ID has been rejected or withdrawn by its CVE Numbering Authority.
CVE-2025-53189 1 Abb 3 Aspect Enterprise, Matrix Series, Nexus Series 2025-08-21 N/A
This CVE ID has been rejected or withdrawn by its CVE Numbering Authority.
CVE-2025-53188 1 Abb 3 Aspect Enterprise, Matrix Series, Nexus Series 2025-08-21 N/A
This CVE ID has been rejected or withdrawn by its CVE Numbering Authority.
CVE-2025-3395 1 Abb 1 Automation Builder 2025-05-28 7.1 High
Incorrect Permission Assignment for Critical Resource, Cleartext Storage of Sensitive Information vulnerability in ABB Automation Builder.This issue affects Automation Builder: through 2.8.0.