| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A vulnerability classified as problematic was found in Lucky LM-520-SC, LM-520-FSC and LM-520-FSC-SAM up to 20250321. Affected by this vulnerability is an unknown functionality. The manipulation leads to missing authentication. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| An authentication bypass vulnerability exists in the User profile management functionality of Socomec Easy Config System 2.6.1.0. A specially crafted database record can lead to unauthorized access. An attacker can modify a local database to trigger this vulnerability. |
| Missing authentication for critical function vulnerability exists in Wi-Fi AP UNIT 'AC-WPS-11ac series'. If exploited, a remote unauthenticated attacker may obtain the product configuration information including authentication information. |
| On the exos 9300 server, a SOAP API is reachable on port 8002. This API does not require any authentication prior to sending requests. Therefore, network access to the exos server allows e.g. the creation of arbitrary access log events as well as querying the 2FA PINs associated with the enrolled chip cards. |
| ESCAM QD-900 WIFI HD cameras contain an unauthenticated configuration disclosure vulnerability in the /web/cgi-bin/hi3510/backup.cgi endpoint. The endpoint allows remote download of a compressed configuration backup without requiring authentication or authorization. The exposed backup can include administrative credentials and other sensitive device settings, enabling an unauthenticated remote attacker to obtain information that may facilitate further compromise of the camera or connected network. |
| The exos 9300 application can be used to configure Access Managers (e.g. 92xx, 9230 and 9290). The configuration is done in a graphical user interface on the dormakaba exos server. As soon as the save button is clicked in exos 9300, the whole configuration is sent to the selected Access Manager via SOAP. The SOAP request is sent without any prior authentication or authorization by default. Though authentication and authorization can be configured using IPsec for 92xx-K5 devices and mTLS for 92xx-K7 devices, it is not enabled by default and must therefore be activated with additional steps.
This insecure default allows an attacker with network level access to completely control the whole environment. An attacker is for example easily able to conduct the following tasks without prior authentication:
- Re-configure Access Managers (e.g. remove alarming system requirements)
- Freely re-configure the inputs and outputs
- Open all connected doors permanently
- Open all doors for a defined time interval
- Change the admin password
- and many more
Network level access can be gained due to an insufficient network segmentation as well as missing LAN firewalls. Devices with an insecure configuration have been identified to be directly exposed to the internet. |
| The Amp’ed RF BT-AP 111 Bluetooth access point's HTTP admin interface does not have an authentication feature, allowing unauthorized access to anyone with network access. |
| GALAYOU G2 cameras stream video output via RTSP streams. By default these streams are protected by randomly generated credentials. However these credentials are not required to access the stream. Changing these values does not change camera's behavior.
The vendor did not respond in any way. Only version 11.100001.01.28 was tested, other versions might also be vulnerable. |
| Due to improper BLE security configurations on the device's GATT server, an adjacent unauthenticated attacker can read and write device control commands through the mobile app service wich could render the device unusable. |
| On Mercku M6a devices through 2.1.0, session tokens remain valid for at least months in some cases. |
| FLIR Thermal Camera F/FC/PT/D Stream firmware version 8.0.0.64 contains an unauthenticated vulnerability that allows remote attackers to access live camera streams without credentials. Attackers can exploit the vulnerability to view unauthorized thermal camera video feeds across multiple camera series without requiring any authentication. |
| SAP NetWeaver Enterprise Portal OBN does not perform proper authentication check for a particular configuration setting. As result, a non-authenticated user can set it to an undesired value causing low impact on integrity. There is no impact on confidentiality or availability of the application. |
| General Bytes Crypto Application Server (CAS) beginning with version 20201208 prior to 20220531.38 (backport) and 20220725.22 (mainline) contains an authentication bypass in the admin web interface. An unauthenticated attacker could invoke the same URL used by the product's default-installation / first-admin creation page and create a new administrative account remotely. By gaining admin privileges, the attacker can change the ATM configuration resulting in redirected funds. Public vendor advisories and multiple independent writeups describe the vulnerability as a call to the page used for initial/default installation / first administration user creation; General Bytes has not publicly published the exact endpoint/parameter name. The issue was actively exploited in the wild against cloud-hosted and standalone CAS deployments (scanning exposed CAS instances on ports 7777/443), and publicly acknowledged by the General Bytes in September 2022. |
| The MinigameCenter module has insufficient restrictions on loading URLs, which may lead to some information leakage. |
| A vulnerability was found in rowboatlabs rowboat up to 8096eaf63b5a0732edd8f812bee05b78e214ee97. It has been rated as critical. Affected by this issue is the function PUT of the file apps/rowboat/app/api/uploads/[fileId]/route.ts of the component Session Handler. The manipulation of the argument params leads to missing authentication. The attack may be launched remotely. Continious delivery with rolling releases is used by this product. Therefore, no version details of affected nor updated releases are available. It is expected that this issue will be fixed in the near future. |
| Remote Control Server, maintained by Steppschuh, 3.1.1.12 allows unauthenticated remote code execution when authentication is disabled, which is the default configuration. The server exposes a custom UDP-based control protocol that accepts remote keyboard input events without verification. An attacker on the same network can issue a sequence of keystroke commands to launch a system shell and execute arbitrary commands, resulting in full system compromise. |
| An insufficient entropy vulnerability in the SecuSUITE Secure Client Authentication (SCA) Server of SecuSUITE versions 5.0.420 and earlier could allow an attacker to potentially enroll an attacker-controlled device to the victim’s account and telephone number. |
| Improper control of framework service permissions with possibility of some sensitive device information leakage. |
| A vulnerability was found in Digistar AG-30 Plus 2.6b. It has been classified as problematic. Affected is an unknown function of the component Login Page. The manipulation leads to improper restriction of excessive authentication attempts. The complexity of an attack is rather high. The exploitability is told to be difficult. The vendor was contacted early about this disclosure but did not respond in any way. |
| Multiple FCNT Android devices provide the original security features such as "privacy mode" where arbitrary applications can be set not to be displayed, etc.
Under certain conditions, and when an attacker can directly operate the device which its screen is unlocked by a user, the provided security features' setting pages may be exposed and/or the settings may be altered, without authentication. For example, specific applications in the device configured to be hidden may be displayed and/or activated. |