CVE-2025-54754 1 Cognex 2 In-sight Camera Firmware, In-sight Explorer 2026-04-15 8 High
An attacker with adjacent access, without authentication, can exploit this vulnerability to retrieve a hard-coded password embedded in publicly available software. This password can then be used to decrypt sensitive network traffic, affecting the Cognex device.
CVE-2025-0936 2026-04-15 6.5 Medium
On affected platforms running Arista EOS with a gNMI transport enabled, running the gNOI File TransferToRemote RPC with credentials for a remote server may cause these remote-server credentials to be logged or accounted on the local EOS device or possibly on other remote accounting servers (i.e. TACACS, RADIUS, etc).
CVE-2022-38694 2026-04-15 7.8 High
In BootRom, there is a possible unchecked write address. This could lead to local escalation of privilege with no additional execution privileges needed.
CVE-2022-38691 1 Unisoc 4 Sc9863a, T310, T610 and 1 more 2026-04-15 7.8 High
In BootROM, there is a possible missing validation for Certificate Type 0. This could lead to local escalation of privilege with no additional execution privileges needed.
CVE-2022-26388 2026-04-15 6.4 Medium
A use of hard-coded password vulnerability may allow authentication abuse.This issue affects ELI 380 Resting Electrocardiograph: Versions 2.6.0 and prior; ELI 280/BUR280/MLBUR 280 Resting Electrocardiograph: Versions 2.3.1 and prior; ELI 250c/BUR 250c Resting Electrocardiograph: Versions 2.1.2 and prior; ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph: Versions 2.2.0 and prior.
CVE-2024-34539 2026-04-15 9.4 Critical
Hardcoded credentials in TerraMaster TOS firmware through 5.1 allow a remote attacker to successfully login to the mail or webmail server. These credentials can also be used to login to the administration panel and to perform privileged actions.
CVE-2025-23008 1 Sonicwall 1 Netextender 2026-04-15 7.2 High
An improper privilege management vulnerability in the SonicWall NetExtender Windows (32 and 64 bit) client allows a low privileged attacker to modify configurations.
CVE-2025-7357 2026-04-15 N/A
LITEON IC48A firmware versions prior to 01.00.19r and LITEON IC80A firmware versions prior to 01.01.12e store FTP-server-access-credentials in cleartext in their system logs.
CVE-2025-1977 1 Moxa 2 Nport 6100-g2 Series, Nport 6200-g2 Series 2026-04-15 N/A
The NPort 6100-G2/6200-G2 Series is affected by an execution with unnecessary privileges vulnerability (CVE-2025-1977) that allows an authenticated user with read-only access to perform unauthorized configuration changes through the MCC (Moxa CLI Configuration) tool. The issue can be exploited remotely over the network with low-attack complexity and no user interaction but requires specific system conditions or configurations to be present. Successful exploitation may result in changes to device settings that were not intended to be permitted for the affected user role, potentially leading to a high impact on the confidentiality, integrity, and availability of the device. No impact on other systems has been identified.
CVE-2025-65009 2026-04-15 N/A
In WODESYS WD-R608U router (also known as WDR122B V2.0 and WDR28) admin password is stored in configuration file as plaintext and can be obtained by unauthorized user by direct references to the resource in question. The vendor was notified early about this vulnerability, but didn't respond with the details of vulnerability or vulnerable version range. Only version WDR28081123OV1.01 was tested and confirmed as vulnerable, other versions were not tested and might also be vulnerable.
CVE-2025-6560 2026-04-15 9.8 Critical
Multiple wireless router models from Sapido have an Exposure of Sensitive Information vulnerability, allowing unauthenticated remote attackers to directly access a system configuration file and obtain plaintext administrator credentials.  The affected models are out of support; replacing the device is recommended.
CVE-2025-14096 1 Radiometer 5 Abl800 Basic Analyzer, Abl800 Flex Analyzer, Abl90 Flex Analyzer and 2 more 2026-04-15 8.4 High
A vulnerability exists in multiple Radiometer products that allow an attacker with physical access to the analyzer possibility to extract credential information. The vulnerability is due to a weakness in the design and insufficient credential protection in operating system. Other related CVE's are CVE-2025-14095 & CVE-2025-14097. Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency. Required Configuration for Exposure: Attacker requires physical access to the analyzer. Temporary work Around: Only authorized people can physically access the analyzer. Permanent solution: Local Radiometer representatives will contact all affected customers to discuss a permanent solution. Exploit Status: Researchers have provided a working proof-of-concept (PoC). Radiometer is not aware of any public exploit code at the time of this publication.
CVE-2025-3920 2026-04-15 N/A
A vulnerability was identified in SUR-FBD CMMS where hard-coded credentials were found within a compiled DLL file. These credentials correspond to a built-in administrative account of the software. An attacker with local access to the system or the application's installation directory could extract these credentials, potentially leading to a complete compromise of the application's administrative functions. This issue was fixed in version 2025.03.27 of the SUR-FBD CMMS software.
CVE-2024-39922 2026-04-15 4.6 Medium
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions). Affected devices store user passwords in plaintext without proper protection. This could allow a physical attacker to retrieve them from the embedded storage ICs.
CVE-2025-43005 2026-04-15 4.3 Medium
SAP GUI for Windows allows an unauthenticated attacker to exploit insecure obfuscation algorithms used by the GuiXT application to store user credentials. While this issue does not impact the Integrity or Availability of the application, it may have a Low impact on the Confidentiality of data.
CVE-2025-42958 1 Sap 2 Netweaver, Sap Netweaver 2026-04-15 9.1 Critical
Due to a missing authentication check in the SAP NetWeaver application on IBM i-series, the application allows high privileged unauthorized users to read, modify, or delete sensitive information, as well as access administrative or privileged functionalities. This results in a high impact on the confidentiality, integrity, and availability of the application.
CVE-2024-4106 2026-04-15 5.3 Medium
A vulnerability has been found in FAST/TOOLS and CI Server. The affected products have built-in accounts with no passwords set. Therefore, if the product is operated without a password set by default, an attacker can break into the affected product. The affected products and versions are as follows: FAST/TOOLS (Packages: RVSVRN, UNSVRN, HMIWEB, FTEES, HMIMOB) R9.01 to R10.04 CI Server R1.01.00 to R1.03.00
CVE-2024-3498 2026-04-15 7.8 High
Attackers can then execute malicious files by enabling certain services of the printer via the web configuration page and elevate its privileges to root. As for the affected products/models/versions, see the reference URL.
CVE-2025-8730 1 Belkin 2 F9k1009, F9k1010 2026-04-15 9.8 Critical
A vulnerability was found in Belkin F9K1009 and F9K1010 2.00.04/2.00.09 and classified as critical. Affected by this issue is some unknown functionality of the component Web Interface. The manipulation leads to hard-coded credentials. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3330 2026-04-15 9.9 Critical
Vulnerability in Spotfire Spotfire Analyst, Spotfire Spotfire Server, Spotfire Spotfire for AWS Marketplace allows In the case of the installed Windows client: Successful execution of this vulnerability will result in an attacker being able to run arbitrary code.This requires human interaction from a person other than the attacker., In the case of the Web player (Business Author): Successful execution of this vulnerability via the Web Player, will result in the attacker being able to run arbitrary code as the account running the Web player process, In the case of Automation Services: Successful execution of this vulnerability will result in an attacker being able to run arbitrary code via Automation Services..This issue affects Spotfire Analyst: from 12.0.9 through 12.5.0, from 14.0 through 14.0.2; Spotfire Server: from 12.0.10 through 12.5.0, from 14.0 through 14.0.3, from 14.2.0 through 14.3.0; Spotfire for AWS Marketplace: from 14.0 before 14.3.0.