Search Results (2314 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-32151 2026-04-15 5.9 Medium
User passwords are decrypted and stored on memory before any user logged in. Those decrypted passwords can be retrieved from the coredump file. As for the details of affected product names, model numbers, and versions, refer to the information provided by the respective vendors listed under [References].
CVE-2025-2556 2026-04-15 4.3 Medium
A vulnerability classified as problematic was found in Audi UTR Dashcam 2.0. Affected by this vulnerability is an unknown functionality of the component Video Stream Handler. The manipulation leads to hard-coded credentials. The attack can only be initiated within the local network. The exploit has been disclosed to the public and may be used. Upgrading to version 2.89 and 2.90 is able to address this issue. It is recommended to upgrade the affected component. The vendor was contacted early about these issues and acted very professional. Version 2.89 is fixing this issue for new customers and 2.90 is going to fix it for existing customers.
CVE-2025-2343 2026-04-15 7.5 High
A vulnerability classified as critical was found in IROAD Dash Cam X5 and Dash Cam X6 up to 20250308. Affected by this vulnerability is an unknown functionality of the component Device Pairing. The manipulation leads to hard-coded credentials. Access to the local network is required for this attack to succeed. The complexity of an attack is rather high. The exploitation appears to be difficult. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-6893 1 Moxa 7 Edf-g1002-bp, Edr-8010, Edr-g9010 and 4 more 2026-04-15 N/A
An Execution with Unnecessary Privileges vulnerability has been identified in Moxa’s network security appliances and routers. A flaw in broken access control has been identified in the /api/v1/setting/data endpoint of the affected device. This flaw allows a low-privileged authenticated user to call the API without the required permissions, thereby gaining the ability to access or modify system configuration data. Successful exploitation may lead to privilege escalation, allowing the attacker to access or modify sensitive system settings. While the overall impact is high, there is no loss of confidentiality or integrity within any subsequent systems.
CVE-2025-46809 1 Suse 2 Manager, Manager Server 2026-04-15 5.7 Medium
A Plaintext Storage of a Password vulnerability in SUSE exposes the credentials for the HTTP proxy in the log files. This issue affects Container suse/manager/4.3/proxy-httpd:4.3.16.9.67.1: from ? before 4.3.33-150400.3.55.2; Container suse/manager/5.0/x86_64/proxy-httpd:5.0.5.7.23.1: from ? before 5.0.14-150600.4.17.1; Container suse/manager/5.0/x86_64/server:5.0.5.7.30.1: from ? before 5.0.14-150600.4.17.1; Image SLES15-SP4-Manager-Proxy-4-3-BYOS: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Proxy-4-3-BYOS-Azure: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Proxy-4-3-BYOS-EC2: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Proxy-4-3-BYOS-GCE: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Server-4-3-BYOS: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Server-4-3-BYOS-Azure: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Server-4-3-BYOS-EC2: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Server-4-3-BYOS-GCE: from ? before 4.3.33-150400.3.55.2; SUSE Manager Proxy Module 4.3: from ? before 4.3.33-150400.3.55.2; SUSE Manager Server Module 4.3: from ? before 4.3.33-150400.3.55.2.
CVE-2025-6949 1 Moxa 7 Edf-g1002-bp, Edr-8010, Edr-g9010 and 4 more 2026-04-15 N/A
An Execution with Unnecessary Privileges vulnerability has been identified in Moxa’s network security appliances and routers. A critical authorization flaw in the API allows an authenticated, low-privileged user to create a new administrator account, including accounts with usernames identical to existing users. In certain scenarios, this vulnerability could allow an attacker to gain full administrative control over the affected device, leading to potential account impersonation. While successful exploitation can severely impact the confidentiality, integrity, and availability of the affected device itself, there is no loss of confidentiality or integrity within any subsequent systems.
CVE-2024-34539 2026-04-15 9.4 Critical
Hardcoded credentials in TerraMaster TOS firmware through 5.1 allow a remote attacker to successfully login to the mail or webmail server. These credentials can also be used to login to the administration panel and to perform privileged actions.
CVE-2025-1394 1 Silabs 1 Emberznet 2026-04-15 N/A
The Ember ZNet stack’s packet buffer manager may read out of bound memory leading to an assert, causing a Denial of Service (DoS).
CVE-2025-8730 1 Belkin 2 F9k1009, F9k1010 2026-04-15 9.8 Critical
A vulnerability was found in Belkin F9K1009 and F9K1010 2.00.04/2.00.09 and classified as critical. Affected by this issue is some unknown functionality of the component Web Interface. The manipulation leads to hard-coded credentials. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-13090 2026-04-15 7 High
A privilege escalation vulnerability may enable a service account to elevate its privileges. The sudo rules configured for a local service account were excessively permissive, potentially allowing administrative access if a malicious actor could execute arbitrary commands as that account. It is important to note that no such vector has been identified in this instance.
CVE-2024-32756 2026-04-15 6.8 Medium
Under certain circumstances the Linux users credentials may be recovered by an authenticated user.
CVE-2023-40067 1 Intel 1 Converged Security Management Engine Firmware 2026-04-15 5.7 Medium
Unchecked return value in firmware for some Intel(R) CSME may allow an unauthenticated user to potentially enable escalation of privilege via physical access.
CVE-2024-8903 2026-04-15 N/A
Local active protection service settings manipulation due to unnecessary privileges assignment. The following products are affected: Acronis Cyber Protect Cloud Agent (Windows, macOS) before build 38565.
CVE-2024-43651 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC models before version 241207101 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y).
CVE-2025-23180 2026-04-15 8 High
CWE-250: Execution with Unnecessary Privileges
CVE-2025-23181 2026-04-15 8 High
CWE-250: Execution with Unnecessary Privileges
CVE-2023-49963 2026-04-15 8.8 High
DYMO LabelWriter Print Server through 2.366 contains a backdoor hard-coded password that could allow an attacker to take control.
CVE-2025-30106 2026-04-15 8.8 High
On IROAD v9 devices, the dashcam has hardcoded default credentials ("qwertyuiop") that cannot be changed by the user. This allows an attacker within Wi-Fi range to connect to the device's network to perform sniffing.
CVE-2025-54754 1 Cognex 2 In-sight Camera Firmware, In-sight Explorer 2026-04-15 8 High
An attacker with adjacent access, without authentication, can exploit this vulnerability to retrieve a hard-coded password embedded in publicly available software. This password can then be used to decrypt sensitive network traffic, affecting the Cognex device.
CVE-2025-5379 2026-04-15 4.3 Medium
A vulnerability classified as critical was found in NuCom NC-WR744G 8.5.5 Build 20200530.307. This vulnerability affects unknown code of the component Console Application. The manipulation of the argument CMCCAdmin/useradmin/CUAdmin leads to hard-coded credentials. The attack can be initiated remotely. The vendor was contacted early about this disclosure but did not respond in any way.