Search Results (2314 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-36081 2026-04-15 9.8 Critical
Westermo EDW-100 devices through 2024-05-03 allow an unauthenticated user to download a configuration file containing a cleartext password. NOTE: this is a serial-to-Ethernet converter that should not be placed at the edge of the network.
CVE-2025-23181 2026-04-15 8 High
CWE-250: Execution with Unnecessary Privileges
CVE-2025-23180 2026-04-15 8 High
CWE-250: Execution with Unnecessary Privileges
CVE-2024-43648 2026-04-15 8.8 High
Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H).  A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y).
CVE-2024-32756 2026-04-15 6.8 Medium
Under certain circumstances the Linux users credentials may be recovered by an authenticated user.
CVE-2024-43650 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects  firmware versions before 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y).
CVE-2024-28023 2026-04-15 5.7 Medium
A vulnerability exists in the message queueing mechanism that if exploited can lead to the exposure of resources or functionality to unintended actors, possibly providing attackers with sensitive information or even execute arbitrary code.
CVE-2025-9380 1 Fnkvision 1 Y215 Cctv Camera 2026-04-15 7.8 High
A vulnerability was identified in FNKvision Y215 CCTV Camera 10.194.120.40. Affected by this issue is some unknown functionality of the file /etc/passwd of the component Firmware. Such manipulation leads to hard-coded credentials. Local access is required to approach this attack. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-52164 2026-04-15 8.2 High
Software GmbH Agorum core open v11.9.2 & v11.10.1 was discovered to store credentials in plaintext.
CVE-2024-10334 2026-04-15 7.3 High
A vulnerability exists in the VideONet product included in the listed System 800xA versions, where VideONet is used.  An attacker who successfully exploited the vulnerability could, in the worst case scenario, stop or manipulate the video feed. This issue affects System 800xA: 5.1.X; System 800xA: 6.0.3.X; System 800xA: 6.1.1.X; System 800xA: 6.2.X.
CVE-2024-43652 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVE-2024-43655 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2025-3920 2026-04-15 N/A
A vulnerability was identified in SUR-FBD CMMS where hard-coded credentials were found within a compiled DLL file. These credentials correspond to a built-in administrative account of the software. An attacker with local access to the system or the application's installation directory could extract these credentials, potentially leading to a complete compromise of the application's administrative functions. This issue was fixed in version 2025.03.27 of the SUR-FBD CMMS software.
CVE-2025-22367 2026-04-15 N/A
The authenticated time setting capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS.
CVE-2024-38427 1 Color 1 Demoiccmax 2026-04-15 8.8 High
In International Color Consortium DemoIccMAX before 85ce74e, a logic flaw in CIccTagXmlProfileSequenceId::ParseXml in IccXML/IccLibXML/IccTagXml.cpp results in unconditionally returning false.
CVE-2025-37128 2 Arubanetworks, Hp 2 Edgeconnect Enterprise, Arubaos 2026-04-15 6.8 Medium
A vulnerability in the web API of HPE Aruba Networking EdgeConnect SD-WAN Gateways could allow an authenticated remote attacker to terminate arbitrary running processes. Successful exploitation could allow an attacker to disrupt system operations, potentially resulting in an unstable system state.
CVE-2025-24375 2026-04-15 5 Medium
Charmed MySQL K8s operator is a Charmed Operator for running MySQL on Kubernetes. Before revision 221, the method for calling a SQL DDL or python based mysql-shell scripts can leak database users credentials. The method mysql-operator calls mysql-shell application rely on writing to a temporary script file containing the full URI, with user and password. The file can be read by a unprivileged user during the operator runtime, due it being created with read permissions (0x644). On other cases, when calling mysql cli, for one specific case when creating the operator users, the DDL contains said users credentials, which can be leak through the same mechanism of a temporary file. All versions prior to revision 221 for kubernetes and revision 338 for machine operators.
CVE-2023-49963 2026-04-15 8.8 High
DYMO LabelWriter Print Server through 2.366 contains a backdoor hard-coded password that could allow an attacker to take control.
CVE-2024-34539 2026-04-15 9.4 Critical
Hardcoded credentials in TerraMaster TOS firmware through 5.1 allow a remote attacker to successfully login to the mail or webmail server. These credentials can also be used to login to the administration panel and to perform privileged actions.
CVE-2024-25825 1 Fydeos 2 Fydeos, Openfyde 2026-04-15 9.8 Critical
FydeOS for PC 17.1 R114, FydeOS for VMware 17.0 R114, FydeOS for You 17.1 R114, and OpenFyde R114 were discovered to be configured with the root password saved as a wildcard. This allows attackers to gain root access without a password.