| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A vulnerability, which was classified as critical, was found in H3C GR-3000AX up to V100R006. Affected is the function EnableIpv6/UpdateWanModeMulti/UpdateIpv6Params/EditWlanMacList/Edit_List_SSID of the file /goform/aspForm of the component HTTP POST Request Handler. The manipulation of the argument param leads to buffer overflow. The attack needs to be initiated within the local network. The exploit has been disclosed to the public and may be used. It is recommended to upgrade the affected component. Other functions might be affected as well. |
| An issue in MikroTik RouterOS v.7.14.2 and SwOS v.2.18 exposes the WebFig management interface over cleartext HTTP by default, allowing an on-path attacker to execute injected JavaScript in the administrator’s browser and intercept credentials. |
| A vulnerability classified as critical has been found in GL.iNet GL-A1300 Slate Plus, GL-AR300M16 Shadow, GL-AR300M Shadow, GL-AR750 Creta, GL-AR750S-EXT Slate, GL-AX1800 Flint, GL-AXT1800 Slate AX, GL-B1300 Convexa-B, GL-B3000 Marble, GL-BE3600 Slate 7, GL-E750, GL-E750V2 Mudi, GL-MT300N-V2 Mango, GL-MT1300 Beryl, GL-MT2500 Brume 2, GL-MT3000 Beryl AX, GL-MT6000 Flint 2, GL-SFT1200 Opal, GL-X300B Collie, GL-X750 Spitz, GL-X3000 Spitz AX, GL-XE300 Puli and GL-XE3000 Puli AX 4.x. Affected is an unknown function of the file plugins.so of the component RPC Handler. The manipulation leads to buffer overflow. It is recommended to upgrade the affected component. |
| wire-ios is an iOS client for the Wire secure messaging application. From Wire iOS 3.111.1 to before 3.124.1, messages that were visible in the view port have been logged to the iOS system logs in clear text. Wire application logs created and managed by the application itself were not affected, especially not the logs users can export and send to Wire support. The iOS logs can only be accessed if someone had (physical) access to the underlying unlocked device. The issue manifested itself by calling canOpenUrl() and passing an invalid URL object. When iOS then performs the check and fails, it logs the contents to the system log. This is not documented behaviour. Wire released an emergency fix with version 3.124.1. As a workaround, users can reset their iOS device to remove the offending logs. Since Wire cannot access or modify iOS system logs, there's no other workaround other than a reset. |
| A vulnerability was found in sparklemotion nokogiri c29c920907366cb74af13b4dc2230e9c9e23b833 and classified as problematic. This issue affects the function hashmap_set_with_hash of the file gumbo-parser/src/hashmap.c. The manipulation leads to heap-based buffer overflow. An attack has to be approached locally. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. The identifier of the patch is ada4708e5a67114402cd3feb70a4e1d1d7cf773a. It is recommended to apply a patch to fix this issue. The project maintainer explains that the affected code was merged into the main branch but the commit never appeared in an official release. |
| On the exos 9300 server, a SOAP API is reachable on port 8002. This API does not require any authentication prior to sending requests. Therefore, network access to the exos server allows e.g. the creation of arbitrary access log events as well as querying the 2FA PINs associated with the enrolled chip cards. |
| Improper buffer restrictions in the UEFI firmware for some Intel(R) Processors may allow a privileged user to potentially enable information disclosure via local access. |
| A vulnerability was found in Netgear WNCE3001 1.0.0.50. It has been classified as critical. This affects the function http_d of the component HTTP POST Request Handler. The manipulation of the argument Host leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. |
| The Honeywell Experion PKS and OneWireless WDM contains a Memory Buffer vulnerability in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to an Overread Buffers, which could result in improper index validation against buffer borders leading to remote code execution.
Honeywell recommends updating to the most recent version of Honeywell Experion PKS:
520.2 TCU9 HF1 and 530.1 TCU3 HF1 and OneWireless: 322.5 and 331.1.
The affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3.The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3. |
| A vulnerability classified as problematic has been found in osrg GoBGP up to 3.37.0. Affected is the function SplitRTR of the file pkg/packet/rtr/rtr.go. The manipulation leads to out-of-bounds read. It is possible to launch the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The name of the patch is e748f43496d74946d14fed85c776452e47b99d64. It is recommended to apply a patch to fix this issue. |
| A vulnerability was found in H3C GR-5400AX V100R009L50 and classified as critical. This issue affects the function UpdateWanparamsMulti/UpdateIpv6params of the file /routing/goform/aspForm. The manipulation of the argument param leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor confirms the existence of this issue. Because they assess the risk as low, they do not have immediate plans for remediation. |
| A vulnerability classified as critical was found in uYanki board-stm32f103rc-berial up to 84daed541609cb7b46854cc6672a275d1007e295. This vulnerability affects the function heartrate1_i2c_hal_write of the file 7.Example/hal/i2c/max30100/Manual/demo2/2/heartrate1_hal.c. The manipulation of the argument num leads to stack-based buffer overflow. Continious delivery with rolling releases is used by this product. Therefore, no version details of affected nor updated releases are available. |
| cgi.c in weborf .0.17, 0.18, 0.19, and 0.20 (before 1.0) lacks '\0' termination of the path for CGI scripts because strncpy is misused. |
| A serial interface can be accessed with physical access to the PCB of Wattsense Bridge devices. After connecting to the interface, access to the bootloader is possible, as well as a Linux login prompt. The bootloader access can be used to gain a root shell on the device. This issue is fixed in recent firmware versions BSP >= 6.4.1. |
| A vulnerability was found in H3C GR-3000AX V100R007L50. It has been classified as critical. Affected is the function UpdateWanParamsMulti/UpdateIpv6Params of the file /routing/goform/aspForm. The manipulation of the argument param leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor confirms the existence of this issue. Because they assess the risk as low, they do not have immediate plans for remediation. |
| z2d is a pure Zig 2D graphics library. z2d v0.7.0 released with a new multi-sample anti-aliasing (MSAA) method, which uses a new buffering mechanism for storing coverage data. This differs from the standard alpha mask surface used for the previous super-sample anti-aliasing (SSAA) method. Under certain circumstances where the path being drawn existed in whole or partly outside of the rendering surface, incorrect bounding could cause out-of-bounds access within the coverage buffer. This affects the higher-level drawing operations, such as Context.fill, Context.stroke, painter.fill, and painter.stroke, when either the .default or .multisample_4x anti-aliasing modes were used. .supersample_4x was not affected, nor was drawing without anti-aliasing. In non-safe optimization modes (consumers compiling with ReleaseFast or ReleaseSmall), this could potentially lead to invalid memory accesses or corruption. z2d v0.7.1 fixes this issue, and it's recommended to upgrade to v0.7.1, or, given the small period of time v0.7.0 has been released, use v0.7.1 immediately, skipping v0.7.0. |
| ALTCHA is privacy-first software for captcha and bot protection. A cryptographic semantic binding flaw in ALTCHA libraries allows challenge payload splicing, which may enable replay attacks. The HMAC signature does not unambiguously bind challenge parameters to the nonce, allowing an attacker to reinterpret a valid proof-of-work submission with a modified expiration value. This may allow previously solved challenges to be reused beyond their intended lifetime, depending on server-side replay handling and deployment assumptions. The vulnerability primarily impacts abuse-prevention mechanisms such as rate limiting and bot mitigation. It does not directly affect data confidentiality or integrity. This issue has been addressed by enforcing explicit semantic separation between challenge parameters and the nonce during HMAC computation. Users are advised to upgrade to patched versions, which include version 1.0.0 of the altcha Golang package, version 1.0.0 of the altcha Rubygem, version 1.0.0 of the altcha pip package, version 1.0.0 of the altcha Erlang package, version 1.4.1 of the altcha-lib npm package, version 1.3.1 of the altcha-org/altcha Composer package, and version 1.3.0 of the org.altcha:altcha Maven package. As a mitigation, implementations may append a delimiter to the end of the `salt` value prior to HMAC computation (for example, `<salt>?expires=<time>&`). This prevents ambiguity between parameters and the nonce and is backward-compatible with existing implementations, as the delimiter is treated as a standard URL parameter separator. |
| A vulnerability has been discovered in Winhex affecting version 16.1 SR-1 and 20.4. This vulnerability consists of a buffer overflow controlling the Structured Exception Handler (SEH) registers. This could allow attackers to execute arbitrary code via a long filename argument. |
| A vulnerability has been identified in Cerberus PRO EN Engineering Tool (All versions), Cerberus PRO EN Fire Panel FC72x IP6 (All versions), Cerberus PRO EN Fire Panel FC72x IP7 (All versions), Cerberus PRO EN Fire Panel FC72x IP8 (All versions < IP8 SR4), Cerberus PRO EN X200 Cloud Distribution IP7 (All versions), Cerberus PRO EN X200 Cloud Distribution IP8 (All versions < V4.3.5618), Cerberus PRO EN X300 Cloud Distribution IP7 (All versions), Cerberus PRO EN X300 Cloud Distribution IP8 (All versions < V4.3.5617), Cerberus PRO UL Compact Panel FC922/924 (All versions < MP4), Cerberus PRO UL Engineering Tool (All versions < MP4), Cerberus PRO UL X300 Cloud Distribution (All versions < V4.3.0001), Desigo Fire Safety UL Compact Panel FC2025/2050 (All versions < MP4), Desigo Fire Safety UL Engineering Tool (All versions < MP4), Desigo Fire Safety UL X300 Cloud Distribution (All versions < V4.3.0001), Sinteso FS20 EN Engineering Tool (All versions), Sinteso FS20 EN Fire Panel FC20 MP6 (All versions), Sinteso FS20 EN Fire Panel FC20 MP7 (All versions), Sinteso FS20 EN Fire Panel FC20 MP8 (All versions < MP8 SR4), Sinteso FS20 EN X200 Cloud Distribution MP7 (All versions), Sinteso FS20 EN X200 Cloud Distribution MP8 (All versions < V4.3.5618), Sinteso FS20 EN X300 Cloud Distribution MP7 (All versions), Sinteso FS20 EN X300 Cloud Distribution MP8 (All versions < V4.3.5617), Sinteso Mobile (All versions). The network communication library in affected systems improperly handles memory buffers when parsing X.509 certificates.
This could allow an unauthenticated remote attacker to crash the network service. |
| A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger. |