| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The /WmAdmin/,/invoke/vm.server/login login page in the Integration Server in Software AG webMethods 10.15.0 before Core_Fix7 allows remote attackers to reach the administration panel and discover hostname and version information by sending an arbitrary username and a blank password to the /WmAdmin/#/login/ URI. |
| Insufficient access checks in Visual Planning Admin Center 8 before v.1 Build 240207 allow attackers in possession of a non-administrative Visual Planning account to utilize functions normally reserved for administrators. The affected functions allow attackers to obtain different types of configured credentials and potentially elevate their privileges to administrator level. |
| Database scanning using username and password stores the credentials in plaintext or encoded format within files at the endpoint. This has been identified as a significant security risk. This will lead to exposure of sensitive information for unauthorized access, potentially leading to severe consequences such as data breaches, unauthorized data manipulation, and compromised system integrity. |
| Requests is a HTTP library. Due to a URL parsing issue, Requests releases prior to 2.32.4 may leak .netrc credentials to third parties for specific maliciously-crafted URLs. Users should upgrade to version 2.32.4 to receive a fix. For older versions of Requests, use of the .netrc file can be disabled with `trust_env=False` on one's Requests Session. |
| The exposure of credentials in the call forwarding configuration module in MeetMe products in versions prior to 2024-09 allows an attacker to gain access to some important assets via configuration files. |
| In SAP NetWeaver Java (Software Update Manager 1.1), under certain conditions when a software upgrade encounters errors, credentials are written in plaintext to a log file. An attacker with local access to the server, authenticated as a non-administrative user, can acquire the credentials from the logs. This leads to a high impact on confidentiality, with no impact on integrity or availability. |
| The affected product is vulnerable due to insufficiently protected credentials, which may allow an attacker to impersonate Elvaco and send false information. |
| Insufficiently protected credentials issue exists in AIPHONE IX SYSTEM and IXG SYSTEM. A network-adjacent unauthenticated attacker may obtain sensitive information such as a username and its password in the address book. |
| A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V05.30). The affected devices contain a secure element which is connected via an unencrypted SPI bus. This could allow an attacker with physical access to the SPI bus to observe the password used for the secure element authentication, and then use the secure element as an oracle to decrypt all encrypted update files. |
| Vue Vben Admin 2.10.1 allows unauthorized login to the backend due to an issue with hardcoded credentials. |
| With address book access, SMB/FTP settings could be modified, redirecting scans and possibly capturing credentials. This requires enabled scan functions and printer access. |
| A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected SIMATIC RTLS Locating Manager Report Clients do not properly protect credentials that are used to authenticate to the server. This could allow an authenticated local attacker to extract the credentials and use them to escalate their access rights from the Manager to the Systemadministrator role. |
| Improper handling of OTP/TOTP/HOTP values in NetKnights GmbH privacyIDEA Authenticator v.4.3.0 on Android allows local attackers with root access to bypass two factor authentication. By hooking into app crypto routines and intercepting decryption paths, attacker can recover plaintext secrets, enabling generation of valid one-time passwords, and bypassing authentication for enrolled accounts. |
| NuCom 11N Wireless Router 5.07.90 contains a privilege escalation vulnerability that allows non-privileged users to access administrative credentials through the configuration backup endpoint. Attackers can send a crafted HTTP GET request to the backup configuration page with a specific cookie to retrieve and decode the admin password in Base64 format. |
| Insufficiently Protected Credentials vulnerability in SicommNet BASEC on SaaS allows Password Recovery.
Passwords are either stored in plain text using reversible encryption, allowing an attacker with sufficient privileges to extract plain text passwords easily.
This issue affects BASEC: from 14 Dec 2021. |
| A passback vulnerability which relates to office/small office multifunction printers and laser printers. |
| EasyFlow GP developed by Digiwin has an Insufficiently Protected Credentials vulnerability, allowing privileged remote attackers to obtain plaintext database account credentials from the system frontend. |
| HCL DRYiCE Optibot Reset Station is impacted by a missing Strict Transport Security Header. This could allow an attacker to intercept or manipulate data during redirection. |
| A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected SIMATIC RTLS Locating Manager Track Viewer Client do not properly protect credentials that are used to authenticate to the server. This could allow an authenticated local attacker to extract the credentials and use them to escalate their access rights from the Manager to the Systemadministrator role. |
| The webserver utilizes basic authentication for its user login to the configuration interface. As encryption is disabled on port 80, it enables potential eavesdropping on user traffic, making it possible to intercept their credentials. |