| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Certain functionality within GMOD Apollo does not require authentication when passed with an administrative username |
| Pinger 1.0 contains a remote code execution vulnerability that allows attackers to inject shell commands through the ping and socket parameters. Attackers can exploit the unsanitized input in ping.php to write arbitrary PHP files and execute system commands by appending shell metacharacters. |
| CLUSTERPRO X for Linux 4.0, 4.1, 4.2, 5.0, 5.1 and 5.2 and EXPRESSCLUSTER X for Linux 4.0, 4.1, 4.2, 5.0, 5.1 and 5.2, CLUSTERPRO X SingleServerSafe for Linux 4.0, 4.1, 4.2, 5.0, 5.1 and 5.2, EXPRESSCLUSTER X SingleServerSafe for Linux 4.0, 4.1, 4.2, 5.0, 5.1 and 5.2 allows an attacker sends specially crafted network packets to the product, arbitrary OS commands may be executed without authentication. |
| SQL injection vulnerability in DIAL's CentrosNet v2.64. Allows an attacker to retrieve, create, update, and delete databases by sending POST and GET requests with the 'ultralogin' parameter in '/centrosnet/ultralogin.php'. |
| Amazon EMR Secret Agent creates a keytab file containing Kerberos credentials. This file is stored in the /tmp/ directory. A user with access to this directory and another account can potentially decrypt the keys and escalate to higher privileges.
Users are advised to upgrade to Amazon EMR version 7.5 or higher. For Amazon EMR releases between 6.10 and 7.4, we strongly recommend that you run the bootstrap script and RPM files with the fix provided in the location below. |
| Infinix devices contain a pre-loaded "com.transsion.agingfunction" application, that exposes an unsecured broadcast receiver. An attacker can communicate with the receiver and force the device to perform a factory reset without any Android system permissions.
After multiple attempts to contact the vendor we did not receive any answer. We suppose this issue affects all Infinix Mobile devices. |
| An unrestricted file upload vulnerability exists in MiniWeb HTTP Server <= Build 300 that allows unauthenticated remote attackers to upload arbitrary files to the server’s filesystem. By abusing the upload handler and crafting a traversal path, an attacker can place a malicious .exe in system32, followed by a .mof file in the WMI directory. This triggers execution of the payload with SYSTEM privileges via the Windows Management Instrumentation service. The exploit is only viable on Windows versions prior to Vista. |
| EPSON WebConfig and Epson Web Control for SEIKO EPSON Projector Products do not restrict excessive authentication attempts. An administrative user's password may be identified through a brute force attack. |
| Talkative IRC v0.4.4.16 is vulnerable to a stack-based buffer overflow when processing specially crafted response strings sent to a connected client. An attacker can exploit this flaw by sending an overly long message that overflows a fixed-length buffer, potentially leading to arbitrary code execution in the context of the vulnerable process. This vulnerability is exploitable remotely and does not require authentication. |
| An unauthenticated user can connect to a publicly accessible database using arbitrary credentials. The system grants full access to the database by leveraging a previously authenticated connection through a "mmBackup" application. This flaw allows attackers to bypass authentication mechanisms and gain unauthorized access to database with sensitive data.
This issue affects Asseco mMedica in versions before 11.9.5. |
| The SunPower PVS6's BluetoothLE interface is vulnerable due to its use of hardcoded encryption parameters and publicly accessible protocol details. An attacker within Bluetooth range could exploit this vulnerability to gain full access to the device's servicing interface. This access allows the attacker to perform actions such as firmware replacement, disabling power production, modifying grid settings, creating SSH tunnels, altering firewall settings, and manipulating connected devices. |
| Moxa’s cellular routers, secure routers, and network security appliances are affected by a critical vulnerability, CVE-2024-9140. This vulnerability allows OS command injection due to improperly restricted commands, potentially enabling attackers to execute arbitrary code. This poses a significant risk to the system’s security and functionality. |
| A vulnerability was detected in Mercury KM08-708H GiGA WiFi Wave2 1.1.14. This affects an unknown function of the component HTTP Header Handler. The manipulation of the argument Host results in stack-based buffer overflow. The attack can be executed remotely. The exploit is now public and may be used. |
| The device enables an unauthorized attacker to execute system commands with elevated privileges. This exploit is facilitated through the use of the 'getcommand' query within the application, allowing the attacker to gain root access. |
| A SQL Injection vulnerability on an endpoint in BEIMS Contractor Web, a legacy product that is no longer maintained or patched by the vendor, allows an unauthorised user to retrieve sensitive database contents via unsanitized parameter input. This vulnerability occurs due to improper input validation on /BEIMSWeb/contractor.asp endpoint and successful exploitation requires a contractor.asp endpoint open to the internet. This vulnerability allows attackers to execute arbitrary SQL commands, compromising the confidentiality, integrity and potentially the availability of the database.
Version 5.7.139
has been confirmed as vulnerable. Other versions have not been confirmed by the vendor and users should assume that all versions of BEIMS Contractor Web may be impacted until further guidance is provided by the vendor. |
| A malicious actor can access camera configuration information, including account credentials, without authenticating when accessing a vulnerable URL. |
| A security vulnerability has been identified in the IBL Software Engineering Visual Weather and derived products (NAMIS, Aero Weather, Satellite Weather). The vulnerability is present in the Product Delivery Service (PDS) component in specific server configurations where the PDS pipeline utilizes the IPDS pipeline with Message Editor Output Filters enabled.
A remote unauthenticated
attacker can exploit this vulnerability to send unauthenticated requests to execute the IPDS pipeline with specially crafted Form Properties, enabling remote execution of arbitrary Python code. This vulnerability could lead to a full system compromise of the affected server, particularly if Visual Weather services are run under a privileged user account—contrary to the documented installation best practices.
Upgrade to the patched versions 7.3.10 (or higher), 8.6.0 (or higher). |
| The grafana plugin SDK bundles build metadata into the binaries it compiles; this metadata includes the repository URI for the plugin being built, as retrieved by running `git remote get-url origin`.
If credentials are included in the repository URI (for instance, to allow for fetching of private dependencies), the final binary will contain the full URI, including said credentials. |
| File upload leading to remote code execution (RCE) in the “melis-cms-slider” module of Melis Technology's Melis Platform. This vulnerability allows an attacker to upload a malicious file via a POST request to '/melis/MelisCmsSlider/MelisCmsSliderDetails/saveDetailsForm' using the 'mcsdetail_img' parameter. |
| CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could
cause a potential arbitrary code execution after a successful Man-In-The-Middle attack followed by sending a
crafted Modbus function call to tamper with memory area involved in memory size computation. |